Prepare the low temperature circuit for the bleeding process

Tyyppi ar · aihe 20.00 · versio 0101 · 2013-05-10

Koskee: ENGINE 275, 279, 285

Ei saatavilla kielellä ”fi”; näytetään kielellä Englanti.

Sijainti

Toimintoryhmä 1 Moottori › 20 Moottorin jäähdytys › 20.00 Yleistä

EinPAS 15 Moottori › 15.25 Moottorin jäähdytysjärjestelmä › 15.25.5 Jäähdytysnestekierto täydellinen

Koskee myös moottoreita/vaihteistoja: 275 ***, 279 ***, 285 ***

AR20.00-P-1145-02R

Prepare the low temperature circuit for the bleeding process

ENGINE

275, 279, 285

Prepare the low temperature circuit for the bleeding process

124 589 00 91 00

Test cap

Shown on engine 275, 285

Prepare the low temperature circuit for the bleeding process

1

Connect connections (A, B) with the service connections of the charge air cooler.

P20.00-2133-04

Prepare the low temperature circuit for the bleeding process

2

Close all valves (C, D, H, HA, O, P) on control unit, Y-fitting and vacuum box.

P20.00-2134-06

Prepare the low temperature circuit for the bleeding process

All connections described in the operation steps 3 to 5 remain intact during the whole filling process. Swapping around of the hoses (E, J, S) leads to destruction of the ventilation devices.

3

Connect coolant feed (J) with connection (N).


4

Connect coolant drain (E) with connection (F).


5

Lay waste air hose (S) in receptacle.

P20.00-2135-06

Prepare the low temperature circuit for the bleeding process

P20.00-2136-07

6


Connect control unit (5) with the test connection - connection (L) to test connection. ENGINE 275, 285
ENGINE 279

8

Connect venturi nozzle (6) with control unit (5) - connection (U) to connection (T).

9

Connect compressed air (Z) with venturi nozzle (6) - compressed air (Z) to connection (M).

Audible air outlet is normal.

Prepare the low temperature circuit for the bleeding process

10

Generate vacuum in control unit (5) - open valve (P).


11

Suction in coolant up to the control unit (5) through regulation at valve (O) (arrow). Close valve (O) again afterwards.

P20.00-2138-04

Prepare the low temperature circuit for the bleeding process

12

Check low-temperature circuit for leaktightness - close valve (P).


The unchanged display (arrow) on the pressure measuring device shows maintenance of the vacuum and therefore the leaktightness of the low-temperature circuit.

P20.00-2137-04

Prepare the low temperature circuit for the bleeding process

P20.00-2139-07

13

Disconnect venturi nozzle (6) from control unit (5).

The display on the pressure measuring device (arrow) must still show a vacuum after ending the preparatory work.