GF09.00-P-2000OHL | Turbocharging, function | 5.5.08 |
ENGINE 642.9 in MODEL 221.0 as of Model Year 09 /Modification Year 08
ENGINE 642.9 in MODEL 221.1 as of Model Year 09 /Modification Year 08
General function requirements
Circuit 61 ON
Charging, general
Charging serves to make an appropriate boost pressure available to the engine in every operating phase and thus to increase engine performance and engine torque. For exhaust gas turbocharging, the flow energy of the exhaust gases is used to drive the turbocharger. The turbocharger draws in fresh air at the compressor intake, compresses it and directs it through the compressor outlet, the charge air pipe, the charge air cooler and the air intake manifold to the engine's individual cylinders.
Turbocharging is regulated by the boost pressure control.
-----------------------------------------------------------------------------------------
The boost pressure is regulated by the CDI control unit (N3/9) depending on the following values and associated components:
- Charge pressure sensor (B5/1)
- Boost pressure temperature sensor (B11/4)
- Charge air temperature sensor (B17/8)
- Pressure sensor downstream of air filter (B28/5)
Temperature sensor upstream of turbocharger (B19/11)
- The injection quantity which is determined via the injection time of fuel injectors (Y76) and the fuel pressure in the rail. The fuel pressure in the rail is detected by the rail pressure sensor (B4/6).
- Exhaust back pressure sensor (B60), for the exhaust back pressure in the exhaust system
- Crankshaft Hall sensor (B70), for the engine speed
-----------------------------------------------------------------------------------------
Function sequence
After evaluating the input signals, the CDI control unit actuates the boost pressure positioner (Y77/1) with a PWM (pulse width modulated) signal, according to the boost pressure map. The position of the guide vanes in the turbocharger are altered via the control linkage on the boost pressure actuator. The adjustable guide vanes modify the flow cross-section through which the exhaust gas flows to the turbine. The guide vanes thus match the gas pressure present at the turbine to the required boost pressure. The turbocharger speed is used to determine the quantity of compress air and thus the boost pressure.
The boost pressure is constantly monitored by the charge pressure sensor and passed on to the CDI control unit.
To protect the turbocharger from thermal and mechanical overload, the CDI control unit monitors the exhaust temperature through the temperature sensor upstream of the turbocharger and the exhaust back pressure through the exhaust back pressure sensor.
The boost pressure is reduced if there is a risk of thermal or the mechanical overload.
The charge air heated by the charging is cooled in the charge air cooler.