gf8370g2000a

Starting heater operation, function

Type gf · topic 83.70 · version 0101 · 2011-10-24

Applies to: MODEL 463 as of 1.6.94 up to 31.5.12 with CODE (H12) Auxiliary heater Webasto Tele Thermo Top S

Where it sits

Function group 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — Series 463

GF83.70-G-2000A

Starting heater operation, function

20.10.11

MODEL 463 as of 1.6.94 up to 31.5.12 with CODE (H12) Auxiliary heater
Webasto Tele Thermo Top S

Starting heater operation, function

P83.70-0216-09

1 Burner housing

2 Heat exchanger

A6m1 Circulating pump

A6m2 Combustion air blower

-----------------------------------------------------------------------------------------

A6n1 Stationary heater/control module

N34 Stationary heater timer

Y23 Stationary heater fuel metering pump

-----------------------------------------------------------------------------------------

Function prerequisites

Coolant temperature 20 °C

Vehicle heater must be set to "max"
(microswitch S46/7 actuated)

Vehicle blower set to stage "1"

Vehicle battery must be sufficiently charged

Stationary heater not in malfunction interlock mode

-----------------------------------------------------------------------------------------

-----------------------------------------------------------------------------------------

Function sequence

1 The green indicator lamp on the stationary heater timer (N34) comes on. Heating operation is started by pressing the button "immediate heating/immediate ventilation" on the stationary heater timer (N34) or by pressing the switch on the associated RF remote control.

2 The combustion air blower (A6m2) and circulating pump (A6m1) start running. The combustion air blower (A6m2) supplies air in the partial load mode at its lowest capacity.

3 Flame monitor (A6r3) checking is started, the flame monitor indicates:

"cold" = no flame, start operation is continued

"hot" = flame, start operation is terminated due to defective flame monitor. Malfunction switch-off is accomplished.

4 The glow pin (A6r2) is switched on. The preglow time of approx. 32 s starts.

5 The preglow time has been completed, the fuel metering pump (Y23) starts pumping fuel:

Gasoline version = full load operation, maximum capacity

Diesel version = partial load operation, minimum capacity

6 The fuel and combustion air form a fuel/air mixture in the burner housing (1)

-----------------------------------------------------------------------------------------

7 The safety time of approx. 85 s for flame formation starts:

The fuel/air mixture is ignited by the glow pin (A6r2), the flame monitor (A6r3) monitors the start of combustion.

8 The safety time is completed, the flame monitor (A6r3) indicates:

"hot" = sufficient flame formation, the glow pin (A6r2)
is switched off.

"cold" = no flame formation or flame formation insufficient, the fuel metering pump (Y23) is switched off and the start operation is repeated once. If flame formation is still not accomplished after repeating the starting operation, a malfunction switch-off is accomplished.

9 The stabilization time of approx. 20 s for the combustion starts. The fuel metering pump (gasoline version) is switched to partial load operation, the coolant heats up.

10 When the coolant temperature has increased to greater than 30 °C, the heater actuates the stationary heater relay terminal 15/30 (K16). This connects the vehicle blower motor (M2) to circuit 30. The vehicle blower starts running and the passenger compartment warms up.

-----------------------------------------------------------------------------------------

Malfunction shut-off

GF83.70-G-3037A

Controlled heater operation

GF83.70-G-2004A

Interruption of heater operation

GF83.70-G-2005A

Termination of heater operation

GF83.70-G-2002A

Stationary heater timer

GF83.70-G-4007A

Combustion air blower

GF83.70-P-4004A

Circulating pump

GF83.70-P-4003A

Flame monitor

GF83.70-P-4006A

Burner housing

GF83.70-P-4000A

Glow pin

GF83.70-P-4005A

Fuel metering pump

GF83.70-P-4008A

Radio frequency remote control

GF83.70-G-4049A

Referenced documents