GF83.70-G-2000A | Starting heater operation, function | 20.10.11 |
MODEL 463 as of 1.6.94 up to 31.5.12 with CODE (H12) Auxiliary heater
Webasto Tele Thermo Top S
P83.70-0216-09
1 Burner housing
2 Heat exchanger
A6m1 Circulating pump
A6m2 Combustion air blower
-----------------------------------------------------------------------------------------
A6n1 Stationary heater/control module
N34 Stationary heater timer
Y23 Stationary heater fuel metering pump
-----------------------------------------------------------------------------------------
Function prerequisites
Coolant temperature 20 °C
Vehicle heater must be set to "max"
(microswitch S46/7 actuated)
Vehicle blower set to stage "1"
Vehicle battery must be sufficiently charged
Stationary heater not in malfunction interlock mode
-----------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------
Function sequence
1 The green indicator lamp on the stationary heater timer (N34) comes on. Heating operation is started by pressing the button "immediate heating/immediate ventilation" on the stationary heater timer (N34) or by pressing the switch on the associated RF remote control.
2 The combustion air blower (A6m2) and circulating pump (A6m1) start running. The combustion air blower (A6m2) supplies air in the partial load mode at its lowest capacity.
3 Flame monitor (A6r3) checking is started, the flame monitor indicates:
"cold" = no flame, start operation is continued
"hot" = flame, start operation is terminated due to defective flame monitor. Malfunction switch-off is accomplished.
4 The glow pin (A6r2) is switched on. The preglow time of approx. 32 s starts.
5 The preglow time has been completed, the fuel metering pump (Y23) starts pumping fuel:
Gasoline version = full load operation, maximum capacity
Diesel version = partial load operation, minimum capacity
6 The fuel and combustion air form a fuel/air mixture in the burner housing (1)
-----------------------------------------------------------------------------------------
7 The safety time of approx. 85 s for flame formation starts:
The fuel/air mixture is ignited by the glow pin (A6r2), the flame monitor (A6r3) monitors the start of combustion.
8 The safety time is completed, the flame monitor (A6r3) indicates:
"hot" = sufficient flame formation, the glow pin (A6r2)
is switched off.
"cold" = no flame formation or flame formation insufficient, the fuel metering pump (Y23) is switched off and the start operation is repeated once. If flame formation is still not accomplished after repeating the starting operation, a malfunction switch-off is accomplished.
9 The stabilization time of approx. 20 s for the combustion starts. The fuel metering pump (gasoline version) is switched to partial load operation, the coolant heats up.
10 When the coolant temperature has increased to greater than 30 °C, the heater actuates the stationary heater relay terminal 15/30 (K16). This connects the vehicle blower motor (M2) to circuit 30. The vehicle blower starts running and the passenger compartment warms up.
-----------------------------------------------------------------------------------------
Referenced documents
- gf8370g2002a Termination of heater operation, function
- gf8370g2004a Controlled heater operation, function
- gf8370g2005a Interruption of heater operation, function
- gf8370g3037a Stationary heater malfunction shut-off, function
- gf8370g4007a Arrangement/purpose/function of stationary heater timer
- gf8370g4049a Stationary heater radio frequency remote control, purpose/design
- gf8370p4000a Burner housing position/task/design
- gf8370p4003a Recirculation pump, location/task
- gf8370p4004a Combustion air blower, location/task
- gf8370p4005a Glow pin, location/task
- gf8370p4006a Flame monitor, location/purpose
- gf8370p4008a Fuel metering pump, location/task