GF83.70-G-2002A | Termination of heater operation, function | 20.10.11 |
MODEL 463 as of 1.6.94 up to 31.5.12 with CODE (H12) Auxiliary heater
Webasto Tele Thermo Top S
P83.70-0216-09
1 Burner housing
2 Heat exchanger
A6m1 Circulating pump
A6m2 Combustion air blower
-----------------------------------------------------------------------------------------
A6n1 Stationary heater control module
N34 Stationary heater timer
Y23 Stationary heater fuel metering pump
-----------------------------------------------------------------------------------------
Function prerequisites:
Heater in controlled heater operation.
Terminating heater operation is accomplished by
pressing the button "immediate heating/immediate ventilation" on the stationary heater timer (N34) or
pressing the switch on the associated RF remote control or
automatic switch-off is accomplished upon exceeding the maximum operating time of 60 min.
-----------------------------------------------------------------------------------------
Function
The controlled heater mode is terminated by switching off the fuel metering pump (Y23) followed by a shut-off delay. The green indicator lamp on the stationary heater timer (N34) goes out.
-----------------------------------------------------------------------------------------
Referenced documents
- gf8370g2004a Controlled heater operation, function
- gf8370g3034a Shut-off delay, function
- gf8370g4007a Arrangement/purpose/function of stationary heater timer
- gf8370g4049a Stationary heater radio frequency remote control, purpose/design
- gf8370p4008a Fuel metering pump, location/task