gf8370g2002a

Termination of heater operation, function

Type gf · topic 83.70 · version 0101 · 2011-10-24

Applies to: MODEL 463 as of 1.6.94 up to 31.5.12 with CODE (H12) Auxiliary heater Webasto Tele Thermo Top S

Where it sits

Function group 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — Series 463

GF83.70-G-2002A

Termination of heater operation, function

20.10.11

MODEL 463 as of 1.6.94 up to 31.5.12 with CODE (H12) Auxiliary heater
Webasto Tele Thermo Top S

Termination of heater operation, function

P83.70-0216-09

1 Burner housing

2 Heat exchanger

A6m1 Circulating pump

A6m2 Combustion air blower

-----------------------------------------------------------------------------------------

A6n1 Stationary heater control module

N34 Stationary heater timer

Y23 Stationary heater fuel metering pump

-----------------------------------------------------------------------------------------

Function prerequisites:

Heater in controlled heater operation.

Terminating heater operation is accomplished by

pressing the button "immediate heating/immediate ventilation" on the stationary heater timer (N34) or

pressing the switch on the associated RF remote control or

automatic switch-off is accomplished upon exceeding the maximum operating time of 60 min.

-----------------------------------------------------------------------------------------

Function

The controlled heater mode is terminated by switching off the fuel metering pump (Y23) followed by a shut-off delay. The green indicator lamp on the stationary heater timer (N34) goes out.

-----------------------------------------------------------------------------------------

Controlled heater operation

GF83.70-G-2004A

Shut-off delay, function

GF83.70-G-3034A

Stationary heater timer

GF83.70-G-4007A

Radio frequency remote control

GF83.70-G-4049A

Fuel metering pump

GF83.70-P-4008A

Referenced documents