AP14.40-D-1490A | Fill AdBlue pressure reservoir | 13.4.12 |
ENGINES 900.9 in MODEL 668, 670 with CODE (MS2) BlueTec 5 (Euro 5)
W14.40-1527-06
1 Pump module
2 Filler connection (on pressure reservoir)
3 Drain button
4 Pump
a Old version
5 Valve element
6 Valve cap
7 Protective cap
B New version
8 Valve element
9 Valve cap (with seal)
Modification notes
| Removing | ||
| Pressure reservoir for pump module changed | ||
1.1 | Remove protective cap (7) from filler connection (2), unscrew valve cap (6) | Old version. | |
1.2 | Unscrew valve cap (9) from filler connection (2) | New version. | |
2 | Completely drain pressure reservoir by operating the valve element (5 or 8) | ||
3 | Unscrew valve element (5 or 8) from filler connection (2) | Use assembly tool for valve element tire valves. | |
4 | Screw new valve element (8) into filler connection (2) | Use assembly tool for valve element tire valves. | |
Fill | |||
5 | Screw pump (4) onto filler connection (2) | Pump | |
6 | Inflate pressure accumulator bladder to specified pressure | If this pressure is too high, then this can be corrected by pressing the drain button (3) on the pump (4). Set specified pressure roughly 0.2 bar higher, because a slight pressure loss of this magnitude is unavoidable because of technical reasons when detaching the filling hose of the pump (4) from the filler connection (2) . | |
7 | Unscrew filling hose of pump (4) from filler connection (2) | Note down set pressure (minus 0.2 bar). | |
| Checking | ||
8 | After a waiting period of 5 minutes, screw filling hose of pump (4) onto filler connection (2) | Observe waiting time. Otherwise the test result may be faulty. | |
Pump | |||
9 | Check pressure in pressure reservoir (2) | If the current pressure matches the noted pressure: | |
Proceed with operation step 10 | |||
If a significant pressure loss is recognizable, the pressure reservoir has to be replaced: | |||
Remove/install pressure reservoir at pump module of exhaust aftertreatment system | |||
10 | Unscrew filling hose of pump (4) from filler connection (2) | Pump | |
| Install | ||
11 | Screw valve cap (9) onto filler connection (2) | |
Check values for exhaust aftertreatment, Blue Tec
Number | Designation | Engine | ||
BE14.40-N-1001-02E | Specified value for operating pressure of pressure reservoir | bar | 3.2 ( 0.2) | |
Exhaust aftertreatment, Blue Tec
Number | Designation | Engine | ||
BA14.40-N-1035-02E | Valve cap on pressure reservoir | Nm | 2 | |
Pump
001 589 00 71 00
Documentos referenciados
- ar1440d2008ad Remover e instalar acumulador de pressão no módulo da bomba do SCR
- ar1440d2008ad
- bt1440w000301a Alterado o acumulador de pressão do módulo da bomba