GF83.75-P-2000I

Function of residual engine heat utilization

4.3.98

MODEL 220

Function of residual engine heat utilization of automatic climate control

Residual engine heat utilization with stationary ventilation allows vehicle to be heated even with ignition OFF. For this, system uses residual heat of engine and leads it via blower into interior. Residual engine heat utilization is only possible with ignition OFF.

After actuation of rest button () on control and operating unit of automatic climate control, the following program process is begun:

Duo valve regulated

Heating water recirculation pump ON

Blower is automatically supplied with control voltage of
1.6 V (with 6 second delay)

Defroster, footwell and air conditioning flaps are automatically adjusted.

Diverter, fresh/circulating air flaps are closed

Activated charcoal canister flap open (no activated coal filter operation possible)

Program end

Repeated actuation of rest button ()

Process of time function of 30 minutes (further actuation is possible). If rear air conditioning system is in REST mode at the same time, operation duration is limited to 15 minutes (current consumption)

With battery voltage below 11 V, REST flashes in display

Ignition ON

During functioning of residual engine heat utilization, no function buttons are accepted apart from rest button () nominal value adjusters and rear window heater button.

Function of residual engine heat utilization of rear air conditioning system

Residual engine heat utilization with stationary ventilation allows vehicle to be heated even with ignition OFF. For this, system uses residual heat of engine and leads it via blower into interior. Residual engine heat utilization is only possible with ignition OFF.

After actuation of rest button () on control and operating unit of automatic climate control, the following program process is begun:

Duo valve regulated

Auxiliary coolant pump ON

Blower is automatically supplied with control voltage of 1.2 V (immediately after switching on)

Actuator motor (manual flap adjustment possible)

Refrigerant shut-off valve closed

Program end

Repeated actuation of rest button ()

Process of time function of 30 minutes (further actuation is possible). If rear air conditioning system is in REST mode at the same time, operation duration is limited to 15 minutes (current consumption)

With battery voltage below 11.5 V REST display moves up in display and a battery symbol appears.

With battery voltage below 11.3 V system switches off.

Ignition ON

During functioning of residual engine heat utilization only rest button (), temperature button () and air distribution regulator are accepted.

Arrangement/purpose/function of rest button

GF83.40-P-2148I

Arrangement/purpose/function of rest button, rear air conditioning system

With code 582 (rear air conditioning system)

GF83.50-P-2107M

Arrangement/purpose/function of auxiliary coolant pump

GF83.20-P-2109I

With code 582 (rear air conditioning system)

GF83.20-P-2109M

Arrangement/purpose/function of duo valve

GF83.20-P-2107I

With code 582 (rear air conditioning system)

GF83.20-P-2107M

Arrangement/purpose/function of heater heat exchanger

GF83.20-P-2108I

With code 582 (rear air conditioning system)

GF83.20-P-2108M

Arrangement/purpose/function of blower

GF83.10-P-2140I

With code 582 (rear air conditioning system)

GF83.10-P-2140M

Referenced documents