Function requirements for thermal management, general points

Circuit 87M ON (engine control ON)

Engine running

Thermal management, general points

The thermal management function of the ME-SFI [ME] control unit (N3/10) is used to regulate the engine coolant temperature by controlling the fan speed.

The fan and the fan speed are controlled according to the following sensors and signals:

- Coolant temperature sensor ()B11/4

- Oil sensor (oil level, temperature and grade) (B40), engine oil temperature

- AAC [KLA] control and operating unit (N22), air conditioning status via the interior CAN (CAN B) and engine compartment CAN (CAN C)

-----------------------------------------------------------------------------------------

Thermal management function sequence

The ME-SFI [ME] control unit actuates the engine and air conditioning electric suction fan with integrated control (M4/7). The nominal fan speed is specified via a PWM signal by the ME-SFI [ME] control unit.

The duty cycle of the PWM signal is 10 to 90%.

Meaning:

10% Fan motor "OFF"

20% Fan motor "ON", minimal rpm

90% Fan motor "ON", maximum rpm

If actuation is faulty, the air fan rotates at the maximum rotational speed (fan emergency mode).

-----------------------------------------------------------------------------------------

The AAC [KLA] control and operating unit sends the air conditioning status via the interior CAN and engine compartment CAN to the ME-SFI [ME] control unit.

If coolant temperature is too high, a warning message is displayed on the left multifunction display (A1p13) by the instrument cluster (A1). To do this the ME-SFI [ME] control unit sends an appropriate signal via the engine compartment CAN to the instrument cluster.

Delayed fan switch off

After "ignition OFF" , the fan motor continues to run for up to
5 min. if the coolant temperature or engine oil temperature is above the specified maximum value.

The PWM signal duty cycle is 40 % maximum while the delayed fan switch-off is active.

If the battery voltage is dropping too much, the delayed fan switch-off is stopped.

Electrical function schematic for thermal management

PE07.61-P-2791-97KC

Component description for ME-SFI [ME] control unit

N3/10

GF07.61-P-6000MOR

Component description for coolant temperature sensor

B11/4

GF07.04-P-6040MOR

Component description for oil sensor

B40

GF18.40-P-2000MOR