ar0100p2410k

Disconnecting, connecting engine wiring harness

유형 ar · 주제 01.00 · 버전 0106 · 1998-12-08

적용 대상: ENGINE 112 in MODEL 210, 208, 202 ENGINE 113 in MODEL 210, 208, 202

“ko”(으)로는 제공되지 않아 영어(으)로 표시합니다.

위치

기능 그룹 1 엔진 › 01 엔진 전체, 엔진 배기, 실린더 헤드, 실린더 크랭크케이스 › 01.00 서문 — 시리즈 202 · 시리즈 208 · 시리즈 210

EinPAS 25 온보드 전기 시스템/네트워크/다기능 › 25.25 메인 배선 › 25.25.20 엔진 배선 — 시리즈 202 · 시리즈 208 · 시리즈 210

엔진/변속기에도 적용: 112 ***, 113 ***

AR01.00-P-2410K

Disconnecting, connecting engine wiring harness

11.6.96

ENGINE 112 in MODEL 210, 208, 202

ENGINE 113 in MODEL 210, 208, 202

Disconnecting, connecting engine wiring harness

P01.00-0368-06

Shown in model 210.082 with engine 112

1 Gray vacuum line

A1 Connector at relay module

A2 Connector at relay module

N3/10 ME-SFI control module

W10 Ground cable, battery

W16/6 Ground cable, right of component compartment

Disconnecting, connecting engine wiring harness

P01.00-0369-06

W11/5 Ground, engine

X4 Circuit 30 terminal block

X22/2 Automatic transmission central connector

Removing, installing

1

Disconnect ground cable (W10), connect

Installation: After connecting, read fault memory, code radio and normalize power windows.

Models with stationary heater: set time of stationary heater.

AR54.10-P-0003A

2

Remove trim panel of control module box

3

Detach vacuum line (1)

Detach at rear of intake manifold.

4

Unplug connector of control module (N3/10)

Release locking bar and separate plug connections.

5

Unplug connector (A1) at relay module (K40/4)

6

Unplug connector (A2) at relay module (K40/4)

7

Unbolt ground cable (W16/6) next to control module box

8

Unbolt terminal block (X4) of circuit 30 at outside of body

Position of terminal block:

- Model 210: right footwell.

- Model 208, 202: left footwell.

Detach cover of cable and pull off protective cap.

9

Unplug central connector (X22/2) of automatic transmission

Remove heat shield for this purpose,.

10

Unbolt engine ground (W11/5)

Fig A: Model 208, 202

Fig B: Model 210

11

Install in the reverse order

12

Read fault memory with HHT and erase

Stored faults which can result from cables being disconnected or from simulation during removal and installation or test work have to be processed and erased in the fault memories after completing the work.

Diagnosis Manual Volume 2, Index 0: Connecting and using test equipment.

참조 문서