ap1440d1490a

Fill AdBlue pressure reservoir

유형 ap · 주제 14.40 · 버전 0201 · 2012-04-19

적용 대상: ENGINES 900.9 in MODEL 668, 670 with CODE (MS2) BlueTec 5 (Euro 5)

“ko”(으)로는 제공되지 않아 영어(으)로 표시합니다.

위치

기능 그룹 1 엔진 › 14 배기 매니폴드, 엔진 브레이크, 배기가스 정화장치 › 14.40 배기가스 후처리, AdBlue — 시리즈 668 · 시리즈 670 · 시리즈 900 (모델 9**)

EinPAS 15 엔진 › 15.40 배기 시스템/배기가스 후처리 시스템 › 15.40.51 펌프/정량기/노즐 — 시리즈 668 · 시리즈 670 · 시리즈 900 (모델 9**)

AP14.40-D-1490A

Fill AdBlue pressure reservoir

13.4.12

ENGINES 900.9 in MODEL 668, 670 with CODE (MS2) BlueTec 5 (Euro 5)

Fill AdBlue pressure reservoir

W14.40-1527-06

1 Pump module

2 Filler connection (on pressure reservoir)

3 Drain button

4 Pump

a Old version

5 Valve element

6 Valve cap

7 Protective cap

B New version

8 Valve element

9 Valve cap (with seal)

Modification notes

5.4.11

Method changed through new special tool

Removing

Pressure reservoir for pump module changed

BT14.40-W-0003-01A

1.1

Remove protective cap (7) from filler connection (2), unscrew valve cap (6)

Old version.

1.2

Unscrew valve cap (9) from filler connection (2)

New version.

2

Completely drain pressure reservoir by operating the valve element (5 or 8)

3

Unscrew valve element (5 or 8) from filler connection (2)

Use assembly tool for valve element tire valves.

4

Screw new valve element (8) into filler connection (2)

Use assembly tool for valve element tire valves.

Fill

5

Screw pump (4) onto filler connection (2)

Pump

*001589007100

6

Inflate pressure accumulator bladder to specified pressure

If this pressure is too high, then this can be corrected by pressing the drain button (3) on the pump (4).

Set specified pressure roughly 0.2 bar higher, because a slight pressure loss of this magnitude is unavoidable because of technical reasons when detaching the filling hose of the pump (4) from the filler connection (2) .

*BE14.40-N-1001-02E

7

Unscrew filling hose of pump (4) from filler connection (2)

Note down set pressure (minus 0.2 bar).

Checking

8

After a waiting period of 5 minutes, screw filling hose of pump (4) onto filler connection (2)

Observe waiting time. Otherwise the test result may be faulty.

Pump

*001589007100

9

Check pressure in pressure reservoir (2)

If the current pressure matches the noted pressure:

*BE14.40-N-1001-02E

Proceed with operation step 10

If a significant pressure loss is recognizable, the pressure reservoir has to be replaced:

Remove/install pressure reservoir at pump module of exhaust aftertreatment system

AR14.40-D-2008AD

10

Unscrew filling hose of pump (4) from filler connection (2)

Pump

*001589007100

Install

11

Screw valve cap (9) onto filler connection (2)

*BA14.40-N-1035-02E

Check values for exhaust aftertreatment, Blue Tec

Number

Designation

Engine
900.9

BE14.40-N-1001-02E

Specified value for operating pressure of pressure reservoir

bar

3.2 ( 0.2)

Exhaust aftertreatment, Blue Tec

Number

Designation

Engine
900.9
in model
668, 670

BA14.40-N-1035-02E

Valve cap on pressure reservoir

Nm

2

Fill AdBlue pressure reservoir

Pump

001 589 00 71 00

참조 문서