D54.10-1163-09
1 | Bolts | 4 | Cover | G1 | Battery | ||
2 | Door sill | 5 | Bolts | S25/20 | Battery main switch (MODEL 906 with CODE E30 (Battery master switch)) | ||
3 | Floor covering | 6 | Ground cable |
MODEL 906.657 with CODE PE4 (Master code bus DCAA Argen company) or with CODE PE5 (Master code BUS platform seating, Argen company) |
7 | Trim |
8 | Bolts |
D54.10-1178-11
Danger ! | Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | |
| Notes on battery | ||
| Remove/install | ||
1 | Turn transmitter key in electronic ignition switch EZS control unit to position "0" | After turning the transmitter key a run-on time of 20 s must be waited for before disconnecting the ground line (6). | |
2 | Detach battery main switch (S25/20) | MODEL 906 | |
If no work is to be carried out in the area of the battery (G1), additional steps can be deleted. | |||
3 | Remove bolts (1) and remove door sill molding (2) | ||
4 | Remove bolts (8) and panel (7) | MODEL 906.657 with CODE PE4 (Master code bus DCAA Argen company) or with CODE PE5 (Master code BUS platform seating, Argen company) | |
5 | Remove floor covering (3) | ||
6 | Loosen bolts (5) | ||
7 | Push cover (4) backwards (arrow) and remove | ||
8 | Disconnect ground cable (6) from battery (G1) | ||
9 | Using a diode test lamp, check the on-board electrical system for voltage between the positive line of the battery (G1) and the disconnected ground line (6) | | |
If the diode test lamp lights up, the on-board electrical system is still active because of a defect in the electrical system. In this case the ground line of the additional battery should be disconnected. | |||
| |||
Detach ground line from additional battery. | |||
| |||
| |||
| |||
Check on-board electrical system after completing work. | |||
10 | Install in the reverse order | ||
11 | Adjust clock and normalize power windows | Only if necessary. |
参照文書
- ah5410p000101a バッテリに関する注意事項
- ah5410p000101a
- ar5410d0007sd
- ar5410d0111m
- ar5410s0007jc
- as5410z000101a ショートおよび未燃焼ガスの流出による火災/爆発の危険。バッテリ電解液/蒸気、ショートおよびアーク放電作用による目、皮膚および粘膜の腐食が原因の火傷/負傷の危険。 バ�