ap2000t208001b

Drain coolant, refill

種別 ap · トピック 20.00 · バージョン 0106 · 2005-07-12

適用: ENGINE 402.970, 441.980, 446.938, 457.944 in MODEL 613

「ja」では利用できません。英語で表示しています。

位置付け

機能グループ 1 エンジン › 20 エンジン冷却 › 20.00 一般 — シリーズ 441(モデル 980) · シリーズ 613

EinPAS 15 エンジン › 15.25 エンジン冷却システム › 15.25.5 全体クーラント回路 — シリーズ 441(モデル 980) · シリーズ 613

エンジン/トランスミッションにも適用: 402 970, 446 938, 457 944

AP20.00-T-2080-01B

Drain coolant, refill

Engine cooling system

Number

Designation

Engine 402.970, 441.980, 446.938, 457.944

BF20.00-N-1001-01D

Coolant capacity

without VOITH retarder

Liter

75...100

with VOITH retarder

Liter

95...120

Specifications for service products

Sheet

BB00.40-P-0310-01A

Sheet

BB00.40-P-0325-02A

Drain coolant, refill

M83.70-0105-01

Drain coolant

1 Disconnect electrical connectors on coolant circulation pumps.

Coolant circulation pumps will be damaged if operated without coolant.

Drain coolant, refill

T83.20-0006-11

Illustrated on Engine 402.970

2 Open heating feed shutoff valve (arrow).

Drain coolant, refill

T83.20-0007-11

Illustrated on Engine 402.970

3 Open heating return shutoff valve.

Drain coolant, refill

T20.00-0004-05

4 Unscrew drain plugs (1, 2, 5, 6, 7) on heating system feed and return lines and engine (drain plug on left and temperature sensor on right of engine housing) and automatic transmission or Voith retarder and drain coolant completely.

When disposing of coolant, the legal requirements and local waste water regulations must be observed.

Arrangement of drain plugs and shut off valves with convector heating

1 Heating feed drain plug

6 Engine drain plug (temperature sensor)

7 Voith retarder drain plug

2 Heating return drain plug

3 Heating feed shutoff valve

4 Heating return shutoff valve

5 Engine drain plug

Drain coolant, refill

T20.00-0003-05

Pouring in coolant

5 Clear any drain openings blocked by deposits.

6 Screw in drain plugs (1, 2, 5, 6, 7).

Check drain plug seals, renew if necessary.

Arrangement of drain plugs and shut off valves with side panel heating

1 Heating feed drain plug

66 Engine drain plug (temperature sensor)

77 Voith retarder drain plug

22 Heating return drain plug

3 Heating feed shutoff valve

4 Heating return shutoff valve

5 Engine drain plug

Drain coolant, refill

T83.70-0004-01

7 Unscrew auxiliary heater bleed screw (8) or open bleed valve.

8 Prepare specified mixture of coolant and fill until coolant emerges from auxiliary heater blow hole

9 Close blow hole.

Drain coolant, refill

M83.70-0105-01

10 Connect electrical connectors on coolant circulation pumps.

11 Turn temperature selector for front heater and floor heater to "MAX".