GF83.70-S-3003A | Heat mode when 50 to 100% of heating capacity is required | 9.11.95 |
MODEL 638 with CODE (H12) Warm water auxiliary heater
S83.70-1016-09
The start of heater operation is completed. The combustion air blower (11) and fuel metering pump (1) deliver at their lowest output in "Part load operation".
If the heat requirement increases, the coolant temperature drops. The heat output must be increased by cooling down the coolant. The thermostat (5) in the coolant circuit signals to the control module (3) that the hot water auxiliary heater (A34) must be switched over to "Full load operation".
The coolant temperature increases again in this operating condition of the hot water auxiliary heater (A34).
If the temperature increases above 80°C, the heat requirement drops and the heat output must be reduced.
The control module (3) receives a signal via the thermostat (5) to switch over the hot water auxiliary heater (A34) to "Part load operation".
The combustion air blower (11) and the fuel metering pump (1) then work in "Part load operation". The combustion air blower (11) reduces its speed down to 1/4 of the maximum speed.
In this operating condition of the hot water auxiliary heater (A34), heat is again removed from the coolant and the coolant temperature drops further. The coolant circulation pump (8) and the vehicle heater blower continue operating.
As the coolant temperature drops the heat requirement increases again. The thermostat (5) signals to the control module (3) that the hot water auxiliary heater (A34) must be switched to "Full load operation" and the full cycle of the heater operation starts all over again.
This change between "Part load and full load operation" continues throughout the period of heater operation when the heat requirement remains unchanged.
A34 | Hot water auxiliary heater | ||
K29 | Vehicle heater blower relay | Is actuated by the control module (3) and then switches on the vehicle heater blower | |
P11 | Diagnostic socket | Installation point: left seat subframe | |
The fault memory of the control module (3) can be read out using the HHT | |||
1 | Fuel metering pump | ||
2 | Glow pin | ||
3 | Stationary heater/auxiliary heater control module | ||
4 | Overheating circuit-breaker | ||
5 | Coolant thermostat | ||
8 | Coolant circulation pump | ||
11 | Combustion air blower |
Referenced documents
- gf8370s4002a Stationary heater/auxiliary heater control module, location/purpose
- gf8370s4003a Coolant circulation pump, location/purpose
- gf8370s4004a Combustion air blower, location/purpose
- gf8370s4005a Glow pin, location/purpose
- gf8370s4008a Fuel metering pump, location/purpose
- gf8370s4010a Coolant thermostat, location/purpose
- gf8370s4011a Overheating protection switch, location/purpose/design/function