gf8050p2004fa

Anti-theft alarm system trigger, function

Type gf · topic 80.50 · version 0100 · 2008-03-11

Applies to: MODEL 203.7 as of model year 09 /YoM 08 model refinement package with CODE (551) Antitheft alarm system (ATA [EDW])

Where it sits

Function group 3 Body › 80 Central locking system, convenience operation, drive authorization systems › 80.50 Anti-theft alarm system (ATA), Interior motion sensor/Tow sensor — Series 203 (models 7**)

GF80.50-P-2004FA

Anti-theft alarm system trigger, function

22.2.08

MODEL 203.7
as of model year 09 /YoM 08 model refinement package
with CODE (551) Antitheft alarm system (ATA [EDW])

General function requirements

Anti-theft alarm system (ATA) activated

ATA alarm triggering, general

If one of the alarm inputs of the activated ATA exits its non-actuated state, an alarm is triggered.

Alarm actuation in the event of undervoltage

The operating voltage of the ATA is defined from
U = 8.5 V to U = 15.5 V. If the voltage drops below
U 8,5 V, it is no longer possible to trigger a visual alarm output. Only an acoustic alarm is triggered. The battery voltage is stored in the ATA alarm memory in the rear SAM control unit with fuse and relay module (N10/2).

------------------------------------------------------------------------------------------

The ATA alarm triggering comprises the following subfunctions:

Function sequence for alarm triggering by opening a door, tailgate or engine hood

Function sequence for alarm actuation with tow-away protection

Function sequence for triggering alarm by interior monitoring
(with code (882) Interior monitoring (only with ATA))

Function sequence for alarm actuation from communication loss to alarm siren (H3/1)

Function sequence for alarm output

------------------------------------------------------------------------------------------

Function sequence for alarm triggering by opening a door, tailgate or engine hood

The rear SAM control unit actuates an alarm as soon as the non-actuated state of one of the following contact switches is interrupted for t > 0.5 s:

- Left front door contact switch (S17/3)

- Right front door contact switch (S17/4)

- Engine hood ATA switch (S62)

- Pawl rotary tumbler switch (S88/4)

Opening the left door is recognized by the left front door contact switch, opening the right door by the right front door contact switch.

The ATA engine hood switch recognizes if the engine hood is open, the locking pawl rotary tumbler switch if the liftgate is open.

The status of the contact switches listed is read in directly by the rear SAM control unit. For a new alarm actuation, the corresponding contact switch must first change to the non-actuated state (debounce time t = 500 ms).

------------------------------------------------------------------------------------------

After a non-actuated state of t = 10 s an alarm can be reactuated by the same contact switch, if an acoustic alarm is not present.

If a locked vehicle is unlocked with the mechanical key and the door is opened, the rear SAM control unit triggers an alarm.

Additional function requirements for alarm actuation by tow-away protection

Tow-away protection not deactivated

Changing vehicle inclination (in relation to horizontal axis) from = 3 to 3.5° at a change rate of
1 0,5° pro min

Function sequence for alarm actuation with tow-away protection

If the ATA inclination sensor (B33) recognizes an alarm-relevant inclination motion, an alarm is output.

The status of the ATA inclination sensor is read in directly by the rear SAM control unit.

------------------------------------------------------------------------------------------

Alarm is recognized before a wheel looses ground contact when lifting the vehicle.

Additional function requirements for alarm actuation by interior monitoring
(with code (882) Interior monitoring (only with ATA))

Interior protection not deactivated

Function sequence for triggering alarm by interior monitoring

The vehicle interior is monitored by the left interior protection transmitter/receiver unit (A26/4).

An open circuit in the rear window glass breakage sensor (B39/4) is recognized and evaluated by the interior protection transmitter/receiver unit. If the events are recognized as alarm-relevant, the interior protection transmitter/receiver unit transmits a corresponding signal to the overhead control panel control unit (N70), which relays a signal to the rear SAM control unit via the interior CAN. The rear SAM control unit initiates an alarm.

------------------------------------------------------------------------------------------

Function sequence for alarm actuation from communication loss to alarm siren

Communication between the rear SAM control unit and alarm siren is accomplished cyclically approx. every t = 700 ms. If the alarm siren does not receive a communication request from the rear SAM control unit within t = 1 s, an acoustic alarm is output. If communication does not take place between the alarm siren and the rear SAM control unit, a visual alarm is output.

If the alarm siren detects a loss of power resulting from disconnecting the connection lines or the battery (G1), it outputs an acoustic alarm automatically.

An alarm is only repeated if a new alarm event is registered after the acoustic alarm was terminated.

------------------------------------------------------------------------------------------

Function sequence for alarm output

The visual alarm is output by the vehicle exterior lights. The following components are actuated:

- By the front SAM control unit with fuse and relay module (N10/1)

- Left turn signal lamp (E1e5)

- Right turn signal lamp (E2e5)

- By the rear SAM control unit:

- Left turn signal lamp (E3e1)

- Right turn signal lamp (E4e1)

- By left front door control unit (N69/1):

- Left outside mirror turn signal lamp (E6/5)

- By right front door control unit (N69/2):

- Right outside mirror turn signal lamp (E6/6)

The acoustic alarm is output by actuating the alarm siren in the rear SAM control unit.

The overhead control panel control unit switches on the interior illumination.

An activated alarm is interrupted under the following conditions:

- Unlocking central locking (CL) with transmitter key (A8/1)

- Switching on c. 15C
(transmitter key is inserted into EIS control unit (N73))

The EIS control unit transmits the corresponding signal via the interior CAN to the rear SAM control unit, which then terminates the activated alarm.

Function schematic for electric anti-theft alarm system, alarm actuation

PE80.50-P-2053-97FA

Instrument cluster, component description

A1

GF54.30-P-6000FA

Front SAM control unit with fuse and relay module, component description

N10/1

GF54.21-P-6070FA

Rear SAM control unit with fuse and relay module, component description

N10/2

GF54.21-P-6030FA

Left front door control unit, component description

N69/1

GF72.29-P-4141FA

Right front door control unit, component description

N69/2

GF72.29-P-4142FA

Overhead control panel control unit, component description

N70

GF82.20-P-5216FA

Interior protection transmitter/receiver unit, component description

A26/4

For code (882) Interior monitoring (with ATA [EDW] only)

GF80.50-P-4116FA

Inclination sensor component description

B33

GF80.50-P-6010FA

Rear window glass breakage sensor, component description

B39/4

For code (882) Interior monitoring (with ATA [EDW] only)

GF80.50-P-4118FA

Lamp unit, component description

E1, E2

GF82.10-P-2017FA

Rear lamp unit component description

E3, E4

GF82.10-P-2018FA

Outside mirror turn signal light, component description

E6/5, E6/6

GF82.10-P-4200FA

Rear dome lamp, component description

E15/3

GF82.20-P-5050FA

Alarm signal horn, component description

H3/1

GF80.50-P-6020FA

Door contact switch, component description

S17/3, S17/4

GF80.20-P-4125FA

ATA hood switch, component description

S62

GF80.50-P-6040FA

Lock pawl rotary tumbler switch, component description

S88/4

GF80.20-P-6062FA

Referenced documents