GF07.61-S-2004A | ME-SFI diagnosis fault memory function | 18.9.98 |
ENGINE 111.950 /980 in MODEL 638.094 /194 /294
The ME-SFI control module checks its inputs and outputs for plausibility and detects possible faults.
When detecting faults and storing them, the following distinction is made:
Faults which are constantly present
Loose contact faults
Reading fault memory
It is only possible to read and erase the stored faults with the HHT with ignition "ON" or with "engine running" at the datalink connector.
The fault memory is erased in the ME-SFI control module if the vehicle battery is disconnected (interruption of circuit 30).
Recognition of faults
Signals above or below limit value (open circuit wiring, short circuit, faulty sensors)
Frequency and duration of the fault
Illogical combination of signals
Function chains with fault
Fault messages through CAN databus from the ETC control module or from the DAS control module
-----------------------------------------------------------------------------------------
Storing faults
When a fault is detected for the first time, it is written to the fault memory together with the ambient data initially as a "suspected fault". If the fault is not confirmed in the subsequent driving cycle, it is erased. If the fault is confirmed, it is stored together with its ambient data.
Faults which no longer occur are automatically erased from the fault memory after not more than 40 warming-up phases.
A warming-up phase is completed if
coolant temperature at start < 35 °C
coolant heated up to > 70 °C
A driving cycle for a test consists of
engine start
the particular test performed
engine switched off
A trip is completed if
all tests and function chains of the emission-relevant faults have been completed at least once since engine start
time after start > 20 minutes
engine temperature >= 70 °C
engine speed > 500 rpm
-----------------------------------------------------------------------------------------
Ambient data/operating conditions
When a fault is detected, the following data are stored:
Fault code
Vehicle speed
Engine speed
Coolant temperature
Intake air temperature
Intake manifold pressure
Engine load state
Ignition angle
Adaptation value of mixture formation
Lambda control state
- Lambda control not enabled
- Lambda control enabled
- Lambda control inhibited (e.g. in the case of fuel shutoff or fault detected)
Further environmental conditions (e.g. fuel tank level, time after end of start, distance since erasing last fault, counterreadings for erasing faults or fault frequency)
Function chains
Are test sequences activated by the ME-SFI control module, e.g. for camshaft timing, purge control and leaktightness of evaporative emission control system.
Consequential faults
If a fault signal is detected and the corresponding fault code is stored, all the tests for which the signal is required as a comparative parameter, are aborted. This prevents consequential faults being stored.
Emergency running mode
If faults are detected, substitute values are formed. The malfunction indicator lamp in the instrument cluster only comes on if the fault was already stored.
Referenced documents
- gf0761s5000a ME-SFI control module position / task / design / function