AR63.20-W-1100A | Replacing complete A-pillar | 7.2.97 |
MODEL 950 /, 952 /, 953, 954 (except 950.5 /6, 952.5 /6, 953.6, 954.5)
W63.20-0001-09
1 MIG weld seam on roof frame
4 MIG welding seams on floor panel
10 Course of separation cut
2 Welding flange to firewall
3 MIG weld seams on firewall
W63.20-0002-06
5 Welding flange to A-pillar outer section (between A and B)
6 Welded connections to roof and window frame
7 MIG weld seam on longitudinal member
8 Welding flange to longitudinal member
9 Roof connection to A-pillar
Danger! | The high voltage used for arc welding presents a lethal hazard. Explosion hazard when welding in the area of highly combustible materials. Injury hazard from welding spatter and UV light while welding. Welding gases are poisonous when inhaled. | Use insulating mats. | |
| General notes on body repair | All models | |
| General notes on welding | Models 950, 952, 953, 954 | |
1 | Mark separation points on firewall, A-pillar outer section and window frame | Provide for separation points on firewall and cowl in area (10). If roof paneling is not damaged, provide separation points for window frame and | |
| Removal | ||
2 | Remove firewall outer section up to cowl | Partial replacement possible | |
3 | Remove window frame | Partial replacement possible | |
4 | Remove roof paneling | Only if damaged | |
With code F07 (S cab) | |||
With code F04 (L cab) | |||
5 | Remove floor panel | Only if damaged | |
With code F07 (S cab) | |||
With code F04 (L cab) | |||
6 | Disconnect welds (6, 7, 8) for A-pillar outer section | It is not necessary to disconnect spot welding flange (5) to the A-pillar inner section (between arrows A and B). | |
7 | Disconnect illustrated connection points | ||
| Installation | ||
8 | Position A-pillar together with adjacent frame and paneling parts | Before welding in | |
Check window opening with temporarily positioned paneling parts (install window to check). | |||
Check door cutout and gaps with temporarily positioned paneling parts. | |||
To position the pillar and firewall paneling use corresponding fixtures from Celette straightening set CC7942. | |||
9 | Tack weld framework components | Check positioning of all parts again. | |
10 | Install A-pillar | Welds as on original part. | |
11 | Install firewall outer section up to cowl | ||
12 | Install window frame | ||
13 | Install A-pillar outer section | ||
14 | Install floor panel | With code F07 (S cab) | |
With code F04 (L cab) | |||
15 | Install roof paneling | With code F07 (S cab) | |
With code F04 (L cab) |
Referenced documents
- ah6000n000101a General information on body repair
- ah6000n000501a General notes on welding
- ar6000w575001a Determining separation points
- ar6000w575002a Removing damaged components
- ar6000w575004a Installing carriers, pillars and panelling parts
- ar6010w110001a Setting up Celette straightening tools
- ar6110w5705a Removing and installing floor panel
- ar6110w5705b Removing and installing floor panel
- ar6225w5750a Removing and installing outer part of firewall up to scuttle
- ar6225w5997a Removing and installing window frame
- ar6320w1102a Removing, installing A-pillar outer part
- ar6510w5702a Removing and installing roof paneling
- ar6510w5750a Remove/install roof paneling front section
- ar7210w1089a Check gaps and installation depth of door
- as0000z000701a The high voltage used for electric welding presents a lethal hazard. Risk of explosion from welding in areas close to highly inflammable materials. Risk of injury from weld splatter and UV-light when welding. Risk of poisoning from