DFI starting quantity control, function

Type gf · emne 07.13 · version 0107 · 1999-05-14

Gælder for: ENGINE 602.982 in MODEL 210.017 /217 /617

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.13 Dieselindsprøjtningssystem fordelerpumpe (EVE, EDC) — Serie 210 (modeller 017, 217, 617) · Serie 602 (modeller 982)

GF07.13-P-3000C

DFI starting quantity control, function

5.7.96

ENGINE 602.982 in MODEL 210.017 /217 /617

DFI starting quantity control, function

P07.13-0237-76

Design

B11 Coolant temperature sensor

K40 Relay module (up to 02/97)

K40/4 Fuse and relay module (as of 03/97)

L5/6 Crankshaft position sensor

N3/8 DFI control module

Y1/1 Electrohydraulic shutoff actuator

Y23/3 DFI distributor injection pump

Y23/3b1 Fuel temperature sensor

Y23/3k1 DFI fuel metering actuator

Y23/3l1 Slide valve actuator

Purpose

Controlling the start quantity in line with the operating state, irrespective of the position of the accelerator pedal.

Function

The crankshaft position and the engine speed are detected by the crankshaft position sensor (L5/6) and passed to the DFI control module (N3/8). In addition, signals for processing the required start quantity are passed through the coolant temperature sensor (B11) and the fuel temperature sensor (Y23/3b1) to the DFI control module (N3/8), these signals being passed on to the fuel

metering control (Y23/3k1), with the feedback of the slide valve actuator (Y23/3l1).

After the engine has started and engine speed is >600 rpm, the start quantity control is deactivated.

The start quantity is controlled irrespective of the position of the accelerator pedal.

Engine speed can be controlled from the accelerator pedal only after it has reached a speed of >600 rpm (the start quantity control is interrupted after idle speed is reached). The higher the coolant temperature, the smaller is the start quantity released by the DFI control module (N3/8).

Relay module (K40) position/design/purpose/function

up to 02/97

GF07.13-P-3101H

Fuse and relay module (K40/4) position/purpose/function

as of 03/97

GF07.13-P-3141H

Fuse and relay module (K40/2)

as of 03/97

DFI control module (N3/8) input signals/output signals/

position/purpose/function

GF07.13-P-3102C

Coolant temperature sensor (B11) position/design/purpose/function

GF07.04-P-5026C

DFI distributor injection pump (Y23/3) purpose/design/function

GF07.02-P-5002C

Fuel temperature sensor (Y23/3b1) position/purpose/function

GF07.04-P-5008C

Crankshaft position sensor (L5/6) position/design/purpose/function

GF07.04-P-4116H

Fuel metering control (Y23/3k1) position/purpose/design/function

GF07.13-P-3160C

Slide valve actuator (Y23/3l1) position/purpose/design/function

GF07.04-P-5031C

Electrohydraulic shutoff actuator (Y1/1) position/design/purpose/function

GF07.04-P-3152C

Henviste dokumenter