GF83.20-W-2000A | Heating with manual temperature control, function | 15.3.96 |
MODEL 950, 952, 953, 954 with BODY 942.899
W83.20-0001-09
1 Motor
2 Transmission
3 Coolant pump
4 Coolant thermostat
5 Radiator
6 Heater flow
7 Heater return
8 Filling volume
9 Expansion volume
10 Additional volume
11 Filler neck
-----------------------------------------------------------------------------------------
12 Pressure relief valve 1
13 Pressure relief valve 2
14 Heat exchanger
15 Plastic friction valve
16 Rotary switch for temperature setting
17 Control cable
18 Check valve
A Standard coolant circuit
-----------------------------------------------------------------------------------------
Task
The task is to manually set the temperature of the cab interior, whereby the various influencing variables (outside temperature, interior temperature, heat exchanger temperature) are not considered.
Function
The coolant recirculated by the coolant pump (3) passes through the engine block in a heated state and reaches the front heater. Here, a heat exchanger (14) is used to deliver heat to the cab air.
-----------------------------------------------------------------------------------------
The plastic friction valve (15) enables the flow area on the heater outlet to be altered and thus the coolant quantity through the heat exchanger to be regulated. The plastic friction valve (15) is directly actuated by means of a Bowden cable (17) from the temperature setting rotary switch (16).
The coolant returns back to the coolant pump (3) via the heater return (7).It is mixed beforehand with cooled coolant from the radiator (5). By far the larger part of the coolant does not flow through the heater, but from the engine to the coolant thermostat (4). Depending on the water temperature, this conveys the coolant through the radiator (5) or directly to the coolant pump (3).
-----------------------------------------------------------------------------------------
| Heater operating unit, heater control and climate control, design/location | ||
| Blower rotary switch, task/function/location | ||
| Temperature rotary switch task/function/location | ||
| Center nozzle temperature control rotary switch, task/function/location | ||
| Air distribution rotary switch, task/function/location | ||
| Illumination for heater, heater control and climate control, task/function/location | ||
| Activated charcoal filter switch, task/design/location | ||
| Blower for heater, heater control and climate control, task | ||
| Resistance control for blower motor, design/task/function/location | ||
| Activated charcoal filter with prefilter for heater, heater control and climate control, design/task/location | ||
| Heat exchanger with control valve, task/location |