ad0761p400010a

ME-SFI fault code description for fuel injectors

Typ ad · téma 07.61 · verze 0104 · 2003-06-06

Platí pro: ENGINE 112.910, 112.911 up to 31.5.00, 112.920, 112.921 up to 31.5.00, 112.923, 112.940 /941 /942 up to 31.5.00, 112.943 ENGINE 112.945 up to 30.11.00 in MODEL 463

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 07 Příprava směsi › 07.61 Systém vstřikování paliva a zapalování zážehového motoru ME — Řada 463

EinPAS 15 Motor › 15.45 Management motoru › 15.45.1 Základní informace — Řada 463

Platí také pro motory/převodovky: 112 910, 112 911, 112 920, 112 921, 112 923, 112 940, 112 941, 112 942, 112 943, 112 945

AD07.61-P-4000-10A

ME-SFI fault code description for fuel injectors

1

Fault code

Cylinder 1 (Y62y1)

Cylinder 2 (Y62y2)

Cylinder 3 (Y62y3)

Cylinder 4 (Y62y4)

Cylinder 5 (Y62y5)

Cylinder 6 (Y62y6)

2

Error storage

Activation of engine diagnostics malfunction indicator lamp (EURO3/4)

or CHECK ENGINE (MIL)

after expiry of test duration and fault

after two successive driving cycles with faults

3

Frequency of test

Continuously

4

Checked signal or status

Current/voltage check at each fuel injector

5

Fault setting conditions

Limit values

Short circuit to ground

Short circuit to + 12 V

Open circuit

Test duration

Voltage < 2.5 V

Current > 4.2 A

No voltage at fuel injector

approx. 4 - 8 V at unloaded output of ME-SFI control module

approx. 1 s

6

Test prerequisites

Battery voltage between 8 - 17.1 V

7

The actuation of each fuel injector is inspected for signs of open and short circuits (to ground or battery voltage). When the output stage is in locked status a short circuit to ground and an open circuit can be detected, whereas for a conducting output stage a short circuit is recognized to the battery voltage.

If a malfunction occurs the output stage is immediately deactivated.

8

If there is a short circuit to ground the corresponding fuel injector is always open.