ad0761p400010ba

Fault code description for fuel injection valves, ME-SFI

ประเภท ad · หัวข้อ 07.61 · เวอร์ชัน 0102 · 2005-08-17

ใช้กับ: ENGINE 113.940 /941 /942 /943 /960 as of 1.6.00 ENGINE 113.948 /961 /963 /964 /965 /966 /967 /968 /969 /971 ENGINE 113.962 as of 1.11.00 in MODEL 463

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 1 Engine › 07 Mixture formation › 07.61 ME fuel injection/ ignition system — ซีรีส์ 463

EinPAS 15 Engine › 15.45 Engine management › 15.45.1 Basic information — ซีรีส์ 463

ใช้กับเครื่องยนต์/เกียร์ด้วย: 113 940, 113 941, 113 942, 113 943, 113 948, 113 960, 113 961, 113 962, 113 963, 113 964, 113 965, 113 966, 113 967, 113 968, 113 969, 113 971

AD07.61-P-4000-10BA

Fault code description for fuel injection valves, ME-SFI

Fuel injectors (Y62y1 to Y62y8)

1

Fault code

( Readout on generic scan tool)

P201D Cylinder 1 (Y62y1) (P0201)

P2020 Cylinder 2 (Y62y2) (P0202)

P2022 Cylinder 3 (Y62y3) (P0203)

P201F Cylinder 4 (Y62y3) (P0204)

P201E Cylinder 5 (Y62y5) (P0205)

P2021 Cylinder 6 (Y62y6) (P0206)

P208A Cylinder 7 (Y62y7) (P0207)

P208B Cylinder 8 (Y62y8) (P0208)

2

Fault storage

Actuation of the engine diagnosis indicator lamp (EURO3/4)

or

CHECK ENGINE (MIL)

after expiry of test duration and fault

following two successive driving cycles with faults

3

Checking frequency

Continuous

4

Checked signal or status

Current/voltage test on respective fuel injector

5

Fault setting conditions

Limit values

Short circuit to ground

Short circuit to +12 V

Open circuit in wiring

Checking duration

Voltage lower than 2.5 volts

Current higher than 4.2 amps

No voltage on fuel injection valve

Approx. 4 to 8 V on under no load output of the ME control unit

approx. 1 seconds

6

Check prerequisites

Battery voltage between 8 and 17 V

7

The actuation of each fuel injector is tested for line interruption and short circuit (to ground or battery voltage). A short circuit to ground and a line discontinuity will be recognized when the output stages are locked, while a short circuit to the battery voltage is recognized when the output stages are conducting.

The output stage is immediately no longer activated when a fault arises.

8

In the event of a short circuit to ground, the corresponding fuel injector is continuously open.