gf8340p2001p

Refrigeration cycle function

Type gf · topic 83.40 · version 0104 · 2008-04-01

Applies to: MODEL 203.0 /2 /7 with CODE (580) Air conditioning (or Tempmatic for USA) with CODE (580) Automatic air conditioning with CODE (581) Automatic air conditioning with CODE (581) Comfort automatic air conditioning up to Model Year 8

Where it sits

Function group 3 Body › 83 Climate control › 83.40 Air conditioning (automatic) — Series 203 (models 0**, 2**, 7**)

GF83.40-P-2001P

Refrigeration cycle function

11.5.06

MODEL 203.0 /2 /7
with CODE (580) Air conditioning (or Tempmatic for USA)
with CODE (580) Automatic air conditioning
with CODE (581) Automatic air conditioning
with CODE (581) Comfort automatic air conditioning
up to Model Year 8

Refrigeration cycle function

P83.40-2610-12

Function diagram

2 Condenser

3 Fluid reservoir

4 Expansion valve

5 Evaporator

A9 Refrigerant compressor

A High pressure (gaseous)

B High pressure (liquid)

C Low pressure (liquid)

D Low pressure (gaseous)

The refrigerant compressor (A9) which is driven by the engine compresses the refrigerant vapor, which heats up in the process. The refrigerant is conducted to the condenser (2).

The surface of the condenser (2) is used to withdraw the compression heat from the refrigerant. The refrigerant liquefies during cooling. As it flows through the fluid reservoir (3) the refrigerant is cleaned of chemical and mechanical impurities. The cooled and liquefied refrigerant flows through the expansion valve (4) into the evaporator (5), which is located in the fresh-air flow. The refrigerant is then vaporized. Through this evaporation process heat is extracted from the fresh air flowing past from outside over the tube and fin system so that air cools down.

The air humidity carried along is converted to condensed water, which is routed to the outside. The air is thus dried. The refrigerant compressor (A9) draws in the refrigerant which has turned gaseous again through the collection of heat and compresses it.

When the engine is running and the blower motor is switched on, the interior can be supplied with cooled air through the various air outlets. The degree of cooling intensity is dependent upon the previously set interior temperature and the output of the blower motor.

Electric fan motor/air conditioning system, location/task/function

GF83.40-P-2151P

Condenser location/task/function

GF83.40-P-2152P

Evaporator location/task/design/function

GF83.40-P-2121P

Fluid reservoir location/task/design/function

GF83.40-P-2122P

Expansion valve, location/task/design/function

GF83.40-P-2123P

Air conditioning coolant temperature sensor location/task/function

GF83.40-P-2155P

Refrigerant pressure and temperature sensor location/task/function

GF83.40-P-2171P

Refrigerant compressor, location/task/design/function

GF83.55-P-2100P

Refrigerant compressor control valve location/task/function

GF83.55-P-2102P

Belt pulley, location/task/design/function

GF83.55-P-2103P

Pressure relief valve location/task/function

GF83.55-P-2104P

Evaporator core temperature sensor, location/task/function

GF83.57-P-2109P

Referenced documents