gf8310p2001a

Vacuum system, function

Type gf · topic 83.10 · version 0102 · 1998-09-11

Applies to: MODEL 210

Where it sits

Function group 3 Body › 83 Climate control › 83.10 Ventilation — Series 210

GF83.10-P-2001A

Vacuum system, function

2.6.97

MODEL 210

Vacuum system, function

P83.25-0302-06

Illustration of automatic heater (HEAT)
and air conditioning (Tempmatic)

35 Cockpit interface

36 Vacuum valve block

44 Vacuum element fresh/recirculated air flap

Y13 Fresh/recirculated air flap switchover valve

mgn Medium green

hbl Light blue

Vacuum system, function

P83.40-0264-06

Illustration of air conditioning (automatic)

35 Cockpit interface

37 Left defroster nozzle flap vacuum element

38 Right defroster nozzle flap vacuum element

41 Center nozzle diverter flap vacuum element

42 Right center nozzle blend flap vacuum element

43 Right footwell flap vacuum element

44 Fresh/recirculated air vacuum element

47 Left center nozzle blend flap vacuum element

48 Left footwell flap vacuum element

Y11 Switchover valve block

Vacuum system for automatic heater (HEAT) and air conditioning (Tempmatic)

The vacuum system for the automatic heater (HEAT) and air conditioning (Tempmatic) serves for control of the fresh air/recirculated air flap.
Vacuum is present at the switchover valve (Y13) from the valve block (36). The switchover valve (Y13) can be opened by pressing the recirculated air button ( ) on the pushbutton control module (N18, N19), which actuates the fresh air/recirculated air flap (44).

Vacuum system for automatic air conditioning (automatic A/C)

With automatic air conditioning (automatic A/C) all flaps
(37-48) for air distribution are controlled by the vacuum system.

Vacuum is present at the switchover valve block (Y11) from the cockpit interface (35). The switchover valve block (Y11) switches to control the individual flaps (37-48) depending on the setting on the pushbutton control module (N22).

Switchover valve, location/purpose/function

GF83.10-P-2155A

Ventilleiste Anordnung/Aufgabe/Funktion

nur bei Code 581a und 498

GF83.10-P-2153A

Defroster nozzle vacuum element, location/purpose/design/function

Only with codes 581a and 498

GF83.10-P-2116A

Blend flap vacuum element, location/purpose/design/function

Only with codes 581a and 498

GF83.10-P-2118A

Footwell flap vacuum element, location/purpose/design/function

Only with codes 581a and 498

GF83.10-P-2120A

Unterdruckelement Frischluft-/Umluftklappe Anordnung/Aufgabe/Funktion

GF83.10-P-2159A

Diverter flap vacuum element, location/purpose/design/function

Only with codes 581a and 498

GF83.10-P-2123A

Referenced documents