Perform protective ground conductor and insulation resistance measurement

Type ar · topic 47.70 · version 0101 · 2020-02-03

Applies to: Engine 780.703 in model 910

Where it sits

Function group 1 Engine › 47 Fuel system, powertrain energy supply › 47.70 Powertrain energy supply — Series 910

EinPAS 16 Fuel/power supply to engine › 16.20 High-voltage on-board electrical system › 16.20.1 Basic information — Series 910

Also applies to engines/gearboxes: 780 703

AR47.70-D-1030-03TE

Perform protective ground conductor and insulation resistance measurement

Danger

Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC)

Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines.

AS00.00-Z-0035-01A

Topical note

General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment

AH00.00-Z-0300-01A

Topical note

Notes on battery

AH54.10-P-0001-01A

000 588 00 19 00 Insulation measuring unit

WS54.00-P-0046B

Engine

780.703 in model 910

High-voltage on-board electrical system potential equalization ground lines

Number

Designation

Engine 780.703 in model 910

BA47.70-N-1009-02TE

Screw, potential equalization ground line/protective ground conductor to DC current charge-connection unit

Nm

7

Only perform protective ground conductor and insulation resistance measurement after the vehicle has been de-energized.
Otherwise test results will be incorrect.

Never perform the protective ground conductor and insulation resistance test at a high-voltage component between "HV+" (plus) and "HV-" (minus).
Otherwise, the high voltage component will be damaged.

Carefully attach probes of insulation resistance tester to high-voltage connections.
Otherwise the high-voltage connections may be damaged.

Perform protective ground conductor and insulation resistance measurement

D47.70-A028-78

Shown on Economic Commission for Europe (ECE) charger feed-in socket (type 2) (alternating current)

L1

Phase L1

PE

Protective earth conductor

L2

Phase L2

1

AC charger feed-in connection

N

Neutral conductor

2

Attachment point

1

Calibrate insulation resistance tester.

Observe manufacturers instructions.

2

Open socket flap at radiator grille.

3

Open cover for AC charger feed-in connection (1).

4

Adjust insulation resistance tester to resistance test.

5

Perform resistance test with insulation resistance tester between protective ground conductor (PE) and attachment point (2) of protective ground conductor (PE) at DC current charge-connection unit for high-voltage battery.

Specified value < 1 (+0.9) Ω

If specified value is not achieved

Check electric line of protective ground conductor (PE) for condition and attachment  .


Then repeat resistance test.

If specified value is not achieved during repeat test

Replace charger feed-in socket.

6

Adjust insulation resistance tester to insulation resistance test and set at 500 V.

7

With a test voltage of 500 V at insulation resistance tester, perform insulation resistance test between phase L1 (L1) and protective ground conductor (PE).

Specified value > 1 MΩ.

If specified value is not achieved

Check electric line of protective ground conductor (PE) for condition and attachment  .


Then repeat resistance test.

If specified value is not achieved during repeat test

Replace charger feed-in socket.

8

With a test voltage of 500 V at insulation resistance tester, perform insulation resistance test between phase L2 (L2) and protective ground conductor (PE).

Specified value > 1 MΩ.

If specified value is not achieved

Check electric line of protective ground conductor (PE) for condition and attachment  .


Then repeat resistance test.

If specified value is not achieved during repeat test

Replace charger feed-in socket.

9

With a test voltage of 500 V at insulation resistance tester, perform insulation resistance test between neutral conductor (N) and protective ground conductor (PE).

Specified value > 1 MΩ.

If specified value is not achieved

Check electric line of protective ground conductor (PE) for condition and attachment  .


Then repeat resistance test.

If specified value is not achieved during repeat test

Replace charger feed-in socket.

Perform protective ground conductor and insulation resistance measurement

D47.70-A029-78

Shown on Economic Commission for Europe (ECE) charger feed-in socket (CCS2) (direct current)

DC-

DC current minus connection

2

Attachment point

DC+

DC current plus connection

4

DC current charge-connection unit feed-in connection

PE

Protective earth conductor

10

Calibrate insulation resistance tester.

Observe manufacturers instructions.

11

Open cover for DC current charge-connection unit feed-in connection (4).

12

Adjust insulation resistance tester to resistance test.

13

Perform resistance test with insulation resistance tester between protective ground conductor (PE) and attachment point (2) of protective ground conductor (PE) at DC current charge-connection unit for high-voltage battery.

Specified value < 1 (+0.9) Ω

If specified value is not achieved

Check electric line of protective ground conductor (PE) for condition and attachment  .


Then repeat resistance test.

If specified value is not achieved during repeat test

Replace charger feed-in socket.

14

Adjust insulation resistance tester to insulation resistance test and set at 500 V.

15

With a test voltage of 500 V at insulation resistance tester, perform insulation resistance test between minus DC connection (DC-) and protective ground conductor (PE).

Specified value > 1 MΩ.

If specified value is not achieved

Check electric line of protective ground conductor (PE) for condition and attachment  .


Then repeat resistance test.

If specified value is not achieved during repeat test

Replace charger feed-in socket.

16

With a test voltage of 500 V at insulation resistance tester, perform insulation resistance test between positive DC connection (DC+) and protective ground conductor (PE).

Specified value > 1 MΩ.

If specified value is not achieved

Check electric line of protective ground conductor (PE) for condition and attachment  .


Then repeat resistance test.

If specified value is not achieved during repeat test

Replace charger feed-in socket.

17

Close socket flap at radiator grille.

Perform protective ground conductor and insulation resistance measurement

Shown on 3-phase HVAC circuit charging cable (3)

3

Charging cable

L1

Phase L1

L2

Phase L2

L3

Phase L3

N

Neutral conductor

PE

Protective earth conductor

P54.10-3957-06

Insulation resistance measurement for 3-phase HVAC circuit (measuring point is charging cable (3))

18

Calibrate insulation resistance tester.

Observe manufacturers instructions.

19

Adjust insulation resistance tester to insulation resistance test and set at 500 V.

20

With a test voltage of 500 V at insulation resistance meter, perform insulation resistance measurement at one of the two connectors of charging cable (3) between phase L1 (L1) and protective ground conductor (PE).

Specified value > 1 MΩ

If specified value is not achieved

Replace charging cable (3).

21

With a test voltage of 500 V at insulation resistance meter, perform insulation resistance measurement at one of the two connectors of charging cable (3) between phase L2 (L2) and protective ground conductor (PE).

Specified value > 1 MΩ.

If specified value is not achieved

Replace charging cable (3).

22

With a test voltage of 500 V at insulation resistance meter, perform insulation resistance measurement at one of the two connectors of charging cable (3) between phase L3 (L3) and protective ground conductor (PE).

Specified value > 1 MΩ.

If specified value is not achieved

Replace charging cable (3).

23

With a test voltage of 500 V at insulation resistance meter, perform insulation resistance measurement at one of the two connectors of charging cable (3) between neutral conductor (N) and protective ground conductor (PE).

Specified value > 1 MΩ.

If specified value is not achieved

Replace charging cable (3).

Referenced documents