Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines.Typ 447 mit Motor 780 | |
Danger | Risk of explosion when using a forming gas with incorrect mixing ratio. Risk of suffocation due to inhalation of forming gas. Risk of injury due to bursting of high-pressure hoses. | Wear safety glasses and protective gloves. No smoking or open flames. Work in well-ventilated rooms only. | |
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | Typ 447 mit Motor 780 | |
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Notes on handling refrigerant R134a | |||
Notes on handling refrigerant R1234yf | |||
| Check | ||
1 | Evacuate air conditioning system. |
| |
Model 447 with code HX1 (R-1234yf refrigerant) | |||
2 | Fill refrigerant circuit with forming gas and check for pressure drop. | ||
| 000 588 19 21 00 Leak tester | ||
| |||
Observe operating instructions for leak tester. | |||
Fill refrigerant circuit with forming gas only when the engine is cold or when the axle drive module is cold. | |||
Model 447 with engine 780Pressure drop in refrigerant circuit filled with test gas | |||
Model 447 with engine 274, 622, 651, 654, model 448Pressure drop in refrigerant circuit filled with test gas | |||
3 | Determine leakage in refrigerant circuit using gas detection unit. | If no pressure drop was detected. | |
| 000 588 03 21 00 Gas detector | ||
Observe operating instructions for gas detection unit. | |||
If leaks are found, | |||
| |||
Replace affected component parts of refrigerant circuit. | |||
4 | Vent forming gas from refrigerant circuit on leak tester. | ||
5 | Fill air conditioning. |
| |
Model 447 with code HX1 (R-1234yf refrigerant) |
Henviste dokumenter
- ah0000z030001a Generelle oplysninger ved køretøjer med højvoltsnet og/eller litium-ion-batteri og/eller gasdrivsystem samt personligt beskyttelsesudstyr
- ah8330n000301a Oplysninger om håndtering af kølemidlet R134a
- ah8330n000401a Fremgangsmåde ved beskadiget eller utæt klimaanlæg
- ah8330p000302a Oplysninger om håndtering af kølemiddel R1234yf
- ar8330s1760e
- ar8330s1760ef
- as0000z003501a Livsfare ved arbejde på komponenter og systemer med U >= 30 V vekselspænding (AC) eller U >= 60 V jævnspænding (DC)
- as8300z000102a Fare for eksplosion ved anvendelse af en formeringsgas med forkert blandingsforhold. Fare for kvælning ved indånding af formeringsgas. Fare for personskade pga. revnede højtryksslanger.
- as8300z000601a Fare for forgiftning ved indånding af overophedede kølemiddeldampe fra et klimaanlæg, der er påfyldt R134a. Fare for personskade ved hud- og øjenkontakt med flydende kølemiddel R134a og ved håndtering af dele, der er under tryk.
- as8300z000701a Brandfare som følge af antænding af kølemiddel R1234yf på varme dele. Fare for forgiftning ved indånding af overophedet kølemiddeldamp. Fare for personskade ved hud- og øjenkontakt med frigjort kølemiddel R1234yf og ved håndtering
- ws4700p0019b
- ws8300p0035b