D43.40-0009-06
1 Electrical wiring
2 Central ground line
A15 Retarder relay box
M36 Retarder
| Checking | ||
1 | Measure gap; adjust if necessary | ||
2 | Check batteries | ||
3 | Check connection of central ground line (2) and connection of electrical line (1) to retarder (M36) | If necessary, repair the central ground line (2), electrical lines (1) and retarder (M36). | |
Danger! | Risk of accident caused by vehicle starting off by itself when engine is running. Risk of injury caused by contusions and burns during starting procedure or when working near the running engine | Secure vehicle to prevent it from moving by itself. | |
4 | Check control unit of retarder (M36) | ||
| |||
If necessary, repair the control unit of the retarder (M36) and/or replace the retarder relay box (A15): | |||
Remove/install relay box of Telma retarder | |||
5 | Check power consumption of retarder (M36) | ||
Current per circuit | |||
| |||
| |||
The measured values must be within the tolerance. | |||
Remove/install solenoids of Telma retarder |
Test values for retarder (electric)
Number | Designation | Model | ||
BE43.40-N-1003-01B | Current per circuit | at 24 V and 20 °C | A | 20 (20%) |
at 12 V and 20 °C | A | 40 (20%) | ||
Commercially available tools
Henviste dokumenter
- ar4340d105001ad
- ar4340d105002ad
- ar4340d1500a
- ar4340d1700ad
- ar4340d1750ad