Air suspension
Number | Designation | Model 219 with AIRmatic code 489 | ||
BA32.22-P-1002-03A | Pressure line of air suspension to central reservoir | Nm | 2 | |
BA32.22-P-1004-03A | Pressure line, air suspension to compressor | Nm | 2 | |
BA32.22-P-1006-03A | Pressure line of air suspension to valve unit | Nm | 2 | |
Suspension struts
Number | Designation | Model | ||
BA32.25-P-1003-04K | Air suspension pressure line to front suspension strut | Nm | 5 | |
BA32.25-P-1004-04K | Air suspension pressure line to rear air spring | Nm | 5 | |
BA32.25-P-1007-04K | Air suspension pressure line at rear axle distributor | Nm | 5 | |
211 589 00 09 00
Wrench socket
Slitting knife
000 589 12 28 00
Repair materials
Number | Designation | Order number |
BR00.45-Z-1002-03A | Leak detection spray | Christof Fischer GmbH, |
BR00.45-Z-1004-03A | Leakage spray for USA | LIQUI MOLY Long Beach, CA 90815 Fax + 1 562 5975269 |
P32.22-2320-06
In the event of damage to the pressure line connections (1a) and pressure lines (4) a pressure line connector (3) or repair screwed connection (1) can be attached.
Ensure that the repair is carried out carefully in order to avoid further leaks.
Shown on air suspension strut
1 Remove compressed-air terminal (1a) from affected component (e.g. air suspension strut) and cut pressure line (4) to suitable length using the knife.
Special care must be taken to ensure that the cut is exactly at a right angle to the pressure line (4).
2 Insert the cutoff pressure line (4) up to the stop or 19.5 mm into the pressure line connector (3).
3 Cut the repair line (2) so as to obtain the original length and shape (straight end or 90° arc) of the line.
Do not kink repair line (2). When cutting off the repair line (2) take into account the insertion depths in the repair screwed connection (1) and pressure line connector (3).
Repair lines (2) supplied from through the spare parts channels, each repair (2), with one straight and one bent end.
-----------------------------------------------------------------------------------------
4 Insert the repair line (2) up to the stop or to a depth of 19.5 mm in the pressure line connector (3).
5 Screw the repair bolted connection (1) into the component in question.
6 Pull plastic guard (1c) out of repair connection (1).
-----------------------------------------------------------------------------------------
7 Insert the repair line (2) into the repair bolted connection (1) up to the stop or to a depth of 19.5 mm.
If necessary mark the repair line (2) at 19.5 mm with a felt-tip pen beforehand.
After insertion the pull back the pressure line (4) slightly so that the circumferential retaining edges inside the clamping ring (1b) engage in the outer surface of the line.
When pulling in or routing the pressure line (4) make sure that the pressure line (4) cannot be twisted once fastened. The pressure line connectors (3) should be attached with cable ties at a suitable point on the vehicle so that chafing of the pressure line (4) or noise are prevented.
If bubbles form at the repair point after a leak test with leak detector spray, it must be checked whether the pressure line (4) is inserted as far as the stop. If bubbles continue to form nevertheless, then the pressure line connector (3) may be defective and a new pressure line connector (3) or a new repair bolted connection (1) should be used.