ar3222p200102tx

Repairing AIRmatic pressure line connection

Type ar · emne 32.22 · version 0106 · 2012-05-09

Gælder for: MODEL 219.3 with CODE (489) Airmatic (semi-active air suspension)

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 2 Chassis › 32 Affjedring › 32.22 Luftaffjedring — Serie 219 (modeller 3**)

EinPAS 20 Undervogn › 20.16 affjedring › 20.16.13 ledning/slange/ventil — Serie 219 (modeller 3**)

AR32.22-P-2001-02TX

Repairing AIRmatic pressure line connection

Air suspension

Number

Designation

Model 219 with AIRmatic code 489

BA32.22-P-1002-03A

Pressure line of air suspension to central reservoir

Nm

2

BA32.22-P-1004-03A

Pressure line, air suspension to compressor

Nm

2

BA32.22-P-1006-03A

Pressure line of air suspension to valve unit

Nm

2

Suspension struts

Number

Designation

Model
219 with
AIRmatic

BA32.25-P-1003-04K

Air suspension pressure line to front suspension strut

Nm

5

BA32.25-P-1004-04K

Air suspension pressure line to rear air spring

Nm

5

BA32.25-P-1007-04K

Air suspension pressure line at rear axle distributor

Nm

5

Repairing AIRmatic pressure line connection
Repairing AIRmatic pressure line connection

211 589 00 09 00

Wrench socket

Slitting knife

000 589 12 28 00

Repair materials

Number

Designation

Order number

BR00.45-Z-1002-03A

Leak detection spray

Christof Fischer GmbH,
Augsburger Str. 289-293,
70327 Stuttgart
Germany
Tel. +49 711 30502-0
Fax +49 711 30502-10
www.kaeltefischer.de

BR00.45-Z-1004-03A

Leakage spray for USA

LIQUI MOLY
Gary Boyd
1820 Clark Avenue

Long Beach, CA 90815
USA
Tel. +1 562 5975519

Fax + 1 562 5975269
www.liqui-moly.com

Repairing AIRmatic pressure line connection

P32.22-2320-06

In the event of damage to the pressure line connections (1a) and pressure lines (4) a pressure line connector (3) or repair screwed connection (1) can be attached.

Ensure that the repair is carried out carefully in order to avoid further leaks.

Shown on air suspension strut

1 Remove compressed-air terminal (1a) from affected component (e.g. air suspension strut) and cut pressure line (4) to suitable length using the knife.

Special care must be taken to ensure that the cut is exactly at a right angle to the pressure line (4).

2 Insert the cutoff pressure line (4) up to the stop or 19.5 mm into the pressure line connector (3).

3 Cut the repair line (2) so as to obtain the original length and shape (straight end or 90° arc) of the line.

Do not kink repair line (2). When cutting off the repair line (2) take into account the insertion depths in the repair screwed connection (1) and pressure line connector (3).

Repair lines (2) supplied from through the spare parts channels, each repair (2), with one straight and one bent end.

-----------------------------------------------------------------------------------------

4 Insert the repair line (2) up to the stop or to a depth of 19.5 mm in the pressure line connector (3).

5 Screw the repair bolted connection (1) into the component in question.

6 Pull plastic guard (1c) out of repair connection (1).

-----------------------------------------------------------------------------------------

7 Insert the repair line (2) into the repair bolted connection (1) up to the stop or to a depth of 19.5 mm.

If necessary mark the repair line (2) at 19.5 mm with a felt-tip pen beforehand.

After insertion the pull back the pressure line (4) slightly so that the circumferential retaining edges inside the clamping ring (1b) engage in the outer surface of the line.

When pulling in or routing the pressure line (4) make sure that the pressure line (4) cannot be twisted once fastened. The pressure line connectors (3) should be attached with cable ties at a suitable point on the vehicle so that chafing of the pressure line (4) or noise are prevented.

If bubbles form at the repair point after a leak test with leak detector spray, it must be checked whether the pressure line (4) is inserted as far as the stop. If bubbles continue to form nevertheless, then the pressure line connector (3) may be defective and a new pressure line connector (3) or a new repair bolted connection (1) should be used.