gf8370p2013a

Stationary heater unit, basic function

Typ gf · téma 83.70 · verze 0101 · 2020-06-24

Platí pro: Model all (CAR) with code 228 (Additional warm water heating)

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.70 Nezávislé topení, přídavné topení, přihřívač — Řada 900 (modely 9**) · Řada 902 (modely 9**) · Řada 904 (modely 918, 919, 924, 925, 938, 943, 957) · Řada 906 (modely 917, 918, 924, 953)

Platí také pro motory/převodovky: 139 ***, 254 ***, 256 ***, 272 ***, 276 ***, 282 ***, 457 9**, 541 9**, 542 9**, 608 ***, 700 4**, 700 420, 700 421, 700 422, 700 423, 715 3**, 715 5**, 722 6**, 722 9**, 724 ***, 724 0**, 724 033, 724 044, 724 045, 724 1**, 724 103, 724 114, 724 115, 724 120, 725 ***, 725 0**, 725 035, 725 037, 725 038, 725 085, 725 1**, 739 390, 739 391, 739 395, 739 396, 739 397, 739 398, 739 399, 740 698, 743 3**, 743 4**, 743 498, 746 971, 924 9**, 924 910, 925 9**, 926 9**

GF83.70-P-2013A

Stationary heater unit, basic function

23.06.2020

Model

all (CAR)

with code 228 (Additional warm water heating)

General

The heater unit is the central component of the stationary heater. It comprises all components necessary for generating heat.

Function requirements

Circuit 30t ON

Stationary heater switched on

Fuel level above fuel reserve

No overvoltage or undervoltage

Interior and outside temperature have been determined.

Stationary heater unit, basic function

Structure
The stationary heater unit (1) is located in front of the front right wheel arch. It essentially consists of the stationary heater control unit (1.1), the combustion-air blower (1.2) and the burner housing (1.3).

1

Stationary heater unit

1.1

Stationary heater control unit

1.2

Combustion air blower

1.3

Burner housing

P83.70-5756-82

Function

The stationary heater control unit (1.1) starts the heating mode by actuating the combustion-air blower (1.2) in the heater (1). It also actuates the glow plug/flame monitor unit and starts a preglow time of approx. 30 s. After expiry of the preglow time, the stationary heater control unit (1.1) actuates the fuel pump directly and the fuel feed starts. The fuel evaporates on a metallic mesh in the burner housing (1.3) and, together with the combustion air, forms a fuel/air mixture, which ignites on the glow plug. A flame is produced which heats the coolant. During heating mode, the glow plug/flame monitor unit performs the function of the flame monitor.

If the flame monitor detects an insufficient temperature (flame failure or insufficient flame formation), the stationary heater control unit (1.1) switches off the stationary heater fuel pump. It then initiates a one-off re-start. If flame formation is still not possible, the stationary heater control unit (1.1) switches off the stationary heater fuel pump and activates the emergency shutoff function with run-on of the combustion-air blower (1.2).

A temperature sensor in the heater (1) measures the temperature in the heater (1). The stationary heater switches off from a temperature of approx. 125 °C. The stationary heater fuel pump also switches off from a temperature of approx. 145 °C.