gf8370w2004a

"Controlled heater operation", function

ประเภท gf · หัวข้อ 83.70 · เวอร์ชัน 0102 · 1999-11-08

ใช้กับ: MODEL 950, 952, 953, 954 with CODE (H64) Hot water auxiliary heater "Eberspächer" D9W '

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — ซีรีส์ 950 · ซีรีส์ 952 · ซีรีส์ 953 · ซีรีส์ 954

GF83.70-W-2004A

"Controlled heater operation", function

30.8.96

MODEL 950, 952, 953, 954 with CODE (H64) Hot water auxiliary heater "Eberspächer" D9W

"Controlled heater operation", function

W83.70-0017-09

1 Timer
2 Control module
3 Glow pin
4 Temperature sensor
5 Burner
6 Heat exchanger
7 Overheating sensor

V Combustion air
A Exhaust
KE Coolant inlet
KA Coolant outlet
KS Fuel

8 Coolant circulation pump
9 Burner housing
10 Flame sensor
11 Combustion air blower
12 Exhaust line with muffler
13 Combustion air line
14 Fuel metering pump
15 Automatic heater control panel

"Controlled heater operation", function
"Controlled heater operation", function

W83.70-0030-01

Heat output stages

P Power

G High

M Medium

K Low

A OFF

Heat output stages

P Power

G High

M Medium

K Low

A OFF

W83.70-0031-01

Temperature thresholds with engine standing still

T Temperature in Celsius

t time

GH Switch-on threshold for blower for vehicle heater

Temperature thresholds while driving

T Temperature in Celsius

t time

GH Switch-on threshold for blower for vehicle heater

Function sequence with engine standing still and while driving

The auxiliary heater is switched on with the timer (1) for the auxiliary heater.

The heater has completed the starting phase and is in the controlled shut-off phase.

The blower for the vehicle heater is running. The temperature in the coolant circuit decreases.

Coolant temperature with engine standing still 68°C:

Coolant temperature while driving 63°C:


- The heater starts up in the heat output stage "medium".

-----------------------------------------------------------------------------------------

The temperature in the coolant circuit increases.

Coolant temperature with engine standing still 79°C:

Coolant temperature while driving 74°C:

- The heater is switched to the heat output stage "low"

The temperature in the coolant circuit continues to increase.

Coolant temperature with engine standing still 85°C:

Coolant temperature while driving 80°C:


- The heater first switches to the cooling phase with shut-off delay and after termination of the delay switches to the controlled shut-off phase.

-----------------------------------------------------------------------------------------

Heat output stages for different heat dissipation rates

When the heat dissipation remains at a constant low or medium rate the heater alternates between the "medium" heat output stage and the controlled shut-off phase.
During the controlled shut-off phase only the coolant circulation pump for the heater continues to run.


-----------------------------------------------------------------------------------------

If the heat dissipation is higher the heater alternates from the "medium" heat output stage and the heat output stages "high" or "power".

If the temperature in the coolant circuit does not decrease to below the switch-on threshold of 63 °C while driving, the heater remains in the controlled shut-off phase.

-----------------------------------------------------------------------------------------

Heat output stages

During controlled operation of the auxiliary heater the combustion air blower and fuel metering pump operate at different heat output stages depending on the coolant temperature.

"Medium" stage

Coolant temperature 68°C 79°C

Combustion air blower = 3000 rpm

Fuel metering pump = 2.6 Hz

"Low" stage

Coolant temperature > 79°C < 85°C

Combustion air blower = 1850 rpm

Fuel metering pump = 1 Hz

Other operating states

After termination of heating operation the heater always switches to a cooling phase with shut-off delay for cooling down and purging the heater. After expiration of this phase the heater switches to the controlled shut-off phase until the heating operation is started again.

Cooling phase with shut-off delay

Coolant temperature > 85°C

Combustion air blower "Low" stage = 1850 rpm

Fuel metering pump = off

Controlled shut-off phase

Coolant temperature > 68°C

Combustion air blower = off

Fuel metering pump = off

Coolant circulation pump = running

Burner housing
Location/purpose/design

GF83.70-W-4000A

Heat exchanger, location/purpose/design

GF83.70-W-4017A

Auxiliary heater control module, location/purpose

GF83.70-W-4015A

Coolant circulation pump, location/purpose/design

GF83.70-W-4018A

Combustion air blower, location/purpose/design

GF83.70-W-4019A

Glow pin, location/purpose/design

GF83.70-W-4020A

Flame monitor, location/purpose/design

GF83.70-W-4021A

Timer, location/purpose/design

GF83.70-W-4022A

Fuel metering pump, location/purpose/design

GF83.70-W-4023A

Coolant temperature sensor, location/purpose/design

GF83.70-W-4024A

Overheating sensor, location/purpose/design

GF83.70-W-4025A

เอกสารที่อ้างถึง