ad0761p400010aa

Fault code description for fuel injection valves, ME-SFI

ประเภท ad · หัวข้อ 07.61 · เวอร์ชัน 0102 · 2005-08-17

ใช้กับ: ENGINE 112.910 /911 /920 /921 /922 /940 /941 /942 /944 as of 1.6.00 ENGINE 112.912 /913 /914 /916 /917 /923 /943 /946 /947 /949 /953 /954 /955 /970 /972 /973 /975 ENGINE 112.945 as of 1.11.00 in MODEL 463

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 1 Engine › 07 Mixture formation › 07.61 ME fuel injection/ ignition system — ซีรีส์ 463

EinPAS 15 Engine › 15.45 Engine management › 15.45.1 Basic information — ซีรีส์ 463

ใช้กับเครื่องยนต์/เกียร์ด้วย: 112 910, 112 911, 112 912, 112 913, 112 914, 112 916, 112 917, 112 920, 112 921, 112 922, 112 923, 112 940, 112 941, 112 942, 112 943, 112 944, 112 945, 112 946, 112 947, 112 949, 112 953, 112 954, 112 955, 112 970, 112 972, 112 973, 112 975

AD07.61-P-4000-10AA

Fault code description for fuel injection valves, ME-SFI

Fuel injectors (Y62y1 to Y62y6)

1

Fault code

( Readout on generic scan tool)

P201D Cylinder 1 (Y62y1) (P0201)

P2021 Cylinder 2 (Y62y2) (P0202)

P201F Cylinder 3 (Y62y3) (P0203)

P201E Cylinder 4 (Y62y4) (P0204)

P2022 Cylinder 5 (Y62y5) (P0205)

P2020 Cylinder 6 (Y62y6) (P0206)

2

Fault storage

Actuation of the engine diagnosis indicator lamp (EURO3/4)

or CHECK ENGINE (MIL) malfunction indicator lamp

after expiry of test duration and fault

following two successive driving cycles with faults

3

Checking frequency

Continuous

4

Checked signal or status

Current/voltage test on respective fuel injector

5

Fault setting conditions

Limit values

Short circuit to ground

Short circuit to +12V

Open circuit in wiring

Checking duration

Voltage lower than 2,5 volts

Current higher than 4,2 amps

No voltage on fuel injection valve

Approx. 4 to 8 V on under no load output of the ME control unit

approx. 1 seconds

6

Check prerequisites

Battery voltage between 8 and 17 V

7

The actuation of each fuel injector is tested for line interruption and short circuit (to ground or battery voltage). A short circuit to ground and a line discontinuity will be recognized when the output stages are locked, while a short circuit to the battery voltage is recognized when the output stages are conducting.

The output stage is immediately no longer activated when a fault arises.

8

In the event of a short circuit to ground, the corresponding fuel injector is continuously open.