ar2000y1142d

Drain/pour in coolant

Tip ar · temă 20.00 · versiune 0101 · 2019-10-21

Valabil pentru: Engine 400.925/926/927/928 in model 831.001/002/005 (LHD)

Nu este disponibil în „ro”; afișat în Engleză.

Încadrare

Grupă funcțională 1 Motor › 20 Răcire motor › 20.00 Generalităţi — Seria 400 (modele 925, 926, 927, 928) · Seria 831 (modele 001, 002, 005)

EinPAS 15 Motor › 15.25 Sistem răcire motor › 15.25.5 Circuit de lichid de răcire complet — Seria 400 (modele 925, 926, 927, 928) · Seria 831 (modele 001, 002, 005)

AR20.00-Y-1142D

Drain/pour in coolant

21.10.2019

Engine

400.925/926/927/928 in model 831.001/002/005

(LHD)

Drain/pour in coolant

Y20.00-0007-07

Coolant draining procedure

1

Pressure cap

2

Radiator drain screw

3

Crankcase drain screw

Drain/pour in coolant

Y20.00-0008-07

Coolant filling procedure

2

Radiator drain screw

3

Crankcase drain screw

4

Expansion tank

Drain/pour in coolant

A

High

B

Low

1

Pressure cap

4

Expansion tank

Y20.00-0009-04

Topical note

Notes on coolant

AH20.00-N-2080-01A

Drain

Warning

Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant.

Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers.
Wear protective gloves, protective clothing and safety glasses.

AS20.00-Z-0001-01A

1

Loosen the pressure cap (1) to reduce the pressure in the cooling system.


Never open the radiator cap while the coolant is in hot condition. Drain the coolant only after it has cooled sufficiently.
To avoid getting scald.

2

Loosen drain screw (2) from radiator and collect coolant in a clean container.

Tighten the drain screw after the coolant has drained.
Check and reuse the coolant drain screw O-ring to prevent coolant leakage.

3

Remove the crankcase drain screw (3) from oil cooler unit.

Collect coolant in a clean container.

Fill

4

Install the crankcase drain screw (3) to the oil cooler unit.


Avoid over tightening of the coolant drain screw.
Failure to follow this cause damage of the drain screw.

Ensure that the coolant drain screw is properly tightened.
Use only recommended coolant and quantity.

Crankcase drain screw to oil cooler unit

*BA20.00-Y-1001-02A

5

Install drain screw (2) to the radiator.

Tighten the drain screw using suitable pliers.

6

Fill coolant through filler plug in the coolant expansion reservoir (4).


Avoid remove the pressure relief cap immediately after running the engine.
This may cause injuries.

Coolant (Filling quantity)

*BF20.00-Y-1001-01A

7

Check level of coolant in coolant expansion reservoir (4) to be filled up to maximum level and tighten the pressure cap (1) properly.


Ensure the O-ring of the coolant expansion reservoir cap is properly tightened to avoid any space between the cap and O-ring.
Failure to follow lead to coolant leakage.

Check

8

Start and run the engine for about 5 minutes and check the coolant level in the coolant expansion reservoir.

Fill coolant till maximum level.

Coolant (Filling quantity)

*BF20.00-Y-1001-01A

9

Visually inspect hoses for any leakages.

Coolant filling

Number

Designation

Engine 400.925/926/927/928 in model 831.001/002/005

BA20.00-Y-1001-02A

Crankcase drain screw to oil cooler unit

Nm

24

Coolant

Number

Designation

Engine 400.925/926/927/928

BF20.00-Y-1001-01A

Coolant (Filling quantity)

Coolant

Litre

8.8

Water

Litre

8.8

Sheet

BB00.40-P-0310-01A

Documente menționate