AD07.61-P-6000-24C | Secondary air injection relay - check electrics - ME-SFI fuel injection system | as of 07/97 and D3 low emission standard |
| Scope of test | Tester/test connection | Operation/ Prerequisite: | Specified value | Possible cause/ Remedy | ||
1.0 | Secondary air injection relay Actuation Models 129/140 (K17) Model 202 fuse and relay module (K40/4) Model 210 relay module (K40) as of 07/97 and D3 low emission standard Power consumption K17, K40, K40/4 |
20 (28C) 3 (3A) | N3/10 N3/10 |
2 (2A) 20 (28C) |
Unplug coupling at coolant temperature sensor (B11/4) and simulate using Ohm decade 2.5 kΩ at sockets 1 and 2. Engine: At idle speed: Ignition: ON: |
11 - 14 V for approx. 0.1 - 0.3 A |
Line Air pump fuse K17, K40, K40/4 ME-SFI control module (N3/10) |