AN43.40-W-1001-04PR | Install pneumatic line for permanent magnet retarder | ||
Danger! | Risk of death caused by working on permanent magnet retarder for groups of persons with implants. Risk of injury caused by burns that may occur due to contact with the hot rotor. | For persons with implants, a minimum distance of 30 cm between the permanent magnet retarder and the body parts of the affected person is to be maintained as a safe distance from the permanent magnet retarder. Do not touch hot or rotating parts. |
Retarder (electric)
Number | Designation | Model | ||
BA43.40-N-1007-01D | Bolt, heat shield to stator | Nm | 20 | |
W43.40-1075-11
1 Release compressed air from ancillary consumer circuit.
2 Remove bolt (1).
3 Remove connector for air line (2).
W43.40-1076-11
4 Insert new connector for air line (3).
5 Fasten new connector for air line (3) using a new bolt (4).
6 Insert connector for air line (2).
Replace O-ring of connector for air line (2).
7 Fasten connector for air line (2) using bolt (1).
8 Route air line (5) along the air lines installed in the vehicle to the front and fix in place with cable ties.
W43.40-1077-11
9 Insert connector for air line (6) into PMR solenoid valve (Y159).
W43.40-1084-11
10 Mount shield (7) to stator (8) .
Documentos referenciados
- as4340z000101a Risco de morte em trabalhos no imã permanente do retarder para os grupos de pessoas com implantes. Risco de lesão pelas queimaduras causadas ao tocar no rotor quente.