S20.20-A025-79
Shown with code HH9 (Semi-automatically controlled air conditioning, TEMPMATIC) and code FY1 (Anti-Theft Protection Package) |
1 | Radiator unit | 6 | Carrier | 9 | Electrical connector | ||
2 | Electrical wiring harness | 7 | Bolts | 10 | Cover | ||
3 | Bolts | 8.1 | Upper part fastener | 11 | Cable | ||
4 | Crossmember | 8.2 | Lower part fastener | 12 | Electrical connector | ||
5 | Carrier |
S20.20-A026-79
Shown with CODE HH9 (Semi-automatically regulated air conditioning, TEMPMATIC) |
1 | Radiator unit | 13 | Left air duct segment | 15 | Electrical connector | ||
4 | Crossmember | 14 | Outside temperature sensor | 16 | Elastomer bearing | ||
6 | Carrier |
17 | Cover |
18 | Retaining clips |
S20.20-A028-76
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Warning | Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. | |
Caution | Risk of injury caused by scraping or cutting body parts on sharp vehicle parts | Always wear protective gloves when working on or near sharp and non-deburred vehicle parts. | |
Topical note | Notes on self-locking nuts and bolts | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R1234yf | |||
Notes on handling refrigerant R134a | |||
| Remove/install | ||
1 | Discharge air conditioning system. |
| |
Model 447 except code HX1 (R-1234yf refrigerant) | |||
2 | Drain off coolant. | ||
3 | Remove front bumper. | ||
4 | Remove resonator box. | ||
5 | Remove low-temperature circuit valve with holder from cooler unit (1). | ||
Do not remove or separate coolant lines and electric line. | |||
6 | Remove differential pressure sensor on cooler unit (1). | ||
Do not remove or separate electric line and pressure hose. | |||
7 | Remove both refrigerant lines on refrigerant condenser. | Engine 654.9 in model 447 | |
8 | Detach electrical connection (9). | Engine 654.9 in model 447 | |
9 | Remove cover (10) from hood catch and unhook cable (11). | ||
10 | Unclip cover (17) from retaining clamps (18) and remove forward in direction of arrow (A). | ||
11 | Disconnect electrical connector from the horn. | Model 447.6/7 | |
12 | Remove electrical wiring harness (2) from carrier (5) and crossmember (4). | ||
13 | Remove screw/bolts (3). | Screw, front module carrier to crossmember | |
14 | Remove screws (7) and remove carrier (5). | ||
15 | Detach electrical connector (12) of fan unit and remove electrical wiring harness from cooler unit (1). | ||
16 | Remove left and right upper section fasteners (8.1) in upward direction. | Clip remover | |
17 | Turn left and right lower section fasteners (8.2) by 90° and remove in upward direction. | ||
18 | Unclip outside temperature sensor (14) from left air duct segment (13). | ||
19 | Disconnect electrical connector (15) at refrigerant pressure and temperature sensor. | Engine 654.9 in model 447 | |
20 | Remove air duct segments on cooler unit (1). | ||
21 | Disconnect coolant hoses from cooler. | Open, close coolant line coupling | |
Set of protective covers | |||
Set of protective caps | |||
22 | Carefully tilt cooler unit (1) at top forward and lift out in upward direction between carrier (6) and crossmember (4). | | |
Helper required. | |||
| Check | ||
23 | Check upper section fastener (8.1) for damage. | If there is a problem, | |
| |||
Replace upper section fastener (8.1). | |||
24 | Check lower section fastener (8.2) for damage. | If there is a problem, | |
| |||
Replace lower section fastener (8.2). | |||
25 | Check elastomer bearings (16) for wear and damage. | If there is a problem, | |
| |||
Replace elastomer bearings (16). | |||
26 | Install in the reverse order. |
001 589 01 91 00
Set of protective covers
001 589 00 91 00
Set of protective caps
452 589 01 63 00
Clip remover
Powiązane dokumenty
- ah0000n000101a Wskazówki dotyczące samozabezpieczających śrub i nakrętek
- ah8330n000301a Wskazówki dotyczące postępowania z czynnikiem chłodzącym R134a
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ah8330p000302a Wskazówki dotyczące obchodzenia się z czynnikiem chłodzącym R1234yf
- ar0704s0025e
- ar0920s0010ea
- ar2000s1048ea
- ar2000s1142e
- ar2020p744101rq Otwieranie i zamykanie złącza przewodu płynu chłodzącego
- ar2020s386509ea
- ar2020s387103ea
- ar8330s0013ea
- ar8330s1760e
- ar8330s1760ef
- ar8820s2000e
- ar8840s2629e
- as0000z001701a Niebezpieczeństwo obrażeńo elementy pojazdu o ostrych krawędziach.
- as2000z000101a Niebezpieczeństwo zranienia skóry i oczu przez poparzenie wytryskującym, gorącympłynem chłodzącym. Niebezpieczeństwo zatrucia na skutek połknięcia płynu chłodzącego
- as8300z000601a Zagrożenie zatruciem na skutek wdychania przegrzanych oparów czynnika chłodzącego R134a. Niebezpieczeństwo obrażeń w przypadku kontaktu płynnego czynnika chłodzącego R134a ze skórą i oczami oraz podczas obchodzenia się z
- as8300z000701a Zagrożenie pożarem na skutek zapłonu czynnika chłodzącego R1234yf przy kontakcie z gorącymi elementami. Niebezpieczeństwo zatrucia na skutek wdychania przegrzanych oparów czynnika chłodzącego. Niebezpieczeństwo obrażeń w przyp