W09.41-1040-09
Shown on engine 924.9 with BlueTEC 4 (Euro IV Standard) |
1 | Charge air pipe | 4 | Charge air hose | 7 | O-ring | ||
2 | Charge air pipe | 5 | Turbocharger | 8 | Screw (only for engine 900.91/92, 924.91/93/94) | ||
3 | Clip | 6 | Clip |
Shown on engine 926.9 with BlueTEC 4 (Euro IV Standard) |
1 | Charge air pipe |
2 | Charge air pipe |
3 | Clip |
4 | Charge air hose |
5 | Turbocharger |
6 | Clip |
7 | O-ring |
G09.41-3181-06
Danger | Risk of death when working on component parts and systems with U >= 25 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Danger | Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves when emptying gas cylinders. Risk of poisoning or suffocation caused by inhaling gas. | Remove any sources of ignition. | |
Warning | Risk of injury. Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | |
Warning | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
Topical note | Notes on self-locking nuts and bolts | ||
Notes on work safety regulations for vehicles with natural gas-powered engines | |||
| Remove/install | ||
1 | Remove charge air pipe (1). |
| |
except natural gas engine | |||
2 | Remove charge air hose (4) from charge air pipe (2). | Clamp, charge air hose to charge air distributor/charge air pipe/charge air cooler | |
3 | Remove screw (8). | Only for engine 900.91/92, 924.91/93/94. | |
4 | Remove screw for clamp (6). | Clamp at charge air distributor/charge air pipe | |
5 | Remove charge air pipe (2). | Installation: Clean sealing surfaces and replace O-ring (7). | |
6 | Seal opening on turbocharger (5). | ||
7 | Install in the reverse order | ||
| Check | ||
8 | Start engine and check charge air pipes (1, 2) for leaktightness with engine running. | See information from body manufacturer. | |
9 | Switch off engine. |
参照文書
- ah0000n000101a セルフロッキング·ナットおよびボルトに関する注意事項
- ah0000n500001h 汚れおよび異物による損傷防止に関する注意事項
- ah0010n100004a 天然ガス駆動エンジン搭載車のための作業安全規定に関する注意事項
- ar0941g1331dd
- ar0941g1331de
- as0000z000201a 高温になっているか、あるいは赤熱している部品を取り扱う場合に、火傷を負うあるいは失明する危険があります。
- as0000z000501a エンジン作動中に車両がひとりでに動き出す危険があります。 スタート時または作動中のエンジンに接触すると、巻き込まれて負傷をする、または火傷をする危険があります。
- as0000z001801a 可燃性のガスの流出や、ガス・タンクのオーバーヒートにより爆発の危険があります。皮膚や目に火傷を負い、負傷する危険があります。ガスが吹き出すことにより、またガス�
- as0000z003501a 30 V交流電圧 (AC) または60 V直流電圧 (DC) がかかった構成部品およびシステムでの作業時の生命の危険