Limiting braking torque by means of coolant temperature, function

Tyyppi gf · aihe 43.30 · versio 0100 · 2005-09-05

Koskee: MODEL 374.6, 375.3 /4, 930, 932, 933, 934, 940, 942, 943, 944, 950.5 /6, 952.5 /6, 953.6, 954.5, 958.2 /4 with CODE (BA1) Performance-optimized Voith retarder

Ei saatavilla kielellä ”fi”; näytetään kielellä Englanti.

Sijainti

Toimintoryhmä 2 Alusta › 43 Jarrujen paineilmaosat, lisäjarrut › 43.30 Hidastin (hydraulinen) — Mallisarja 374 (mallit 6**) · Mallisarja 375 (mallit 3**, 4**) · Mallisarja 930 · Mallisarja 932 · Mallisarja 933 · Mallisarja 934 · Mallisarja 940 · Mallisarja 942 · Mallisarja 943 · Mallisarja 944 · Mallisarja 950 (mallit 5**, 6**) · Mallisarja 952 (mallit 5**, 6**) · Mallisarja 953 (mallit 6**) · Mallisarja 954 (mallit 5**) · Mallisarja 958 (mallit 2**, 4**)

GF43.30-W-3000BA

Limiting braking torque by means of coolant temperature, function

25.1.05

MODEL 374.6, 375.3 /4, 930, 932, 933, 934, 940, 942, 943, 944, 950.5 /6, 952.5 /6, 953.6, 954.5, 958.2 /4 with CODE (BA1) Performance-optimized Voith retarder

Limiting braking torque by means of coolant temperature, function

W43.30-1177-76

Illustrated on model 930

A20 Retarder control (RS) control unit

B65 Coolant temperature sensor

CAN 1 Vehicle CAN

P2 Instrument (INS)

P2h8 Permanent brake indicator lamp

Y114 Retarder valve block

Function sequence

1 The retarder control unit (A20) is supplied with information regarding the coolant temperature from the coolant temperature sensor (B65).

2 If the coolant temperature rises into the temperature limiting range during a retarder brake application, the control current to the retarder proportioning valve is reduced linearly for a short time. The actuating pressure is limited, thus limiting the retarder braking torque.

3 After this a constant coolant temperature is regulated:
If the measured coolant temperature is smaller than the maximum permissible coolant temperature the actuating pressure is increased continually. In the opposite case the actuating pressure is reduced continuously.

4 The retarder brake torque and thus the heat accumulating reduce until an equilibrium arises between the accumulating retarder brake energy and the thermal energy which can be dissipated via the vehicle cooling system.

While the limitation of retarder brake energy is effective as a result of too high coolant temperature, the permanent brake indicator lamp flashes (P2h8).

Retarder control (RS) control unit, component description

Model 930, 932, 933, 934

GF43.30-W-3202BA

Model 374.6, 375.3/4, 940, 942, 943, 944, 950.5/6, 952.5/6, 953.6, 954.5, 958.2/4

GF43.30-W-3202BB

Retarder valve block, component description

GF43.30-W-3205BA

Coolant temperature sensor, component description

GF43.30-W-3213BA

Viitatut asiakirjat