gf9130s2001s

Switch off seat heater, function

Type gf · topic 91.30 · version 0102 · 2005-10-18

Applies to: MODEL 639.601 /603 /605 /701 /703 /705 /711 /713 /811 /813 /815 with CODE (H16) Heater for driver seat with CODE (H15) Heater for front passenger seat

Where it sits

Function group 3 Body › 91 Seats, bunks, restraint systems › 91.30 Seat heater, seat ventilation — Series 639 (models 601, 603, 605, 701, 703, 705, 711, 713, 811, 813, 815)

GF91.30-S-2001S

Switch off seat heater, function

27.1.04

MODEL 639.601 /603 /605 /701 /703 /705 /711 /713 /811 /813 /815
with CODE (H16) Heater for driver seat
with CODE (H15) Heater for front passenger seat

Function requirements:

Circuit 15R ON

Heated seats (SIH) system is activated

No overvoltage or undervoltage

Heating stage 1 of the SIH system is deactivated by pressing the left front SIH switch (N72/1s2) or the right front SIH switch (N72/1s10) up again. This is indicated by the one light emitting diode (LED) in the left front SIH switch (N72/1s2) or the right front SIH seat (N72/1s10) going out.

Heating stage 2 of the SIH system is deactivated by pressing the left front SIH switch (N72/1s2) or the right front SIH switch (N72/1s10) down again. This is indicated by the 2 LEDs in the left front SIH switch (N72/1s2) or the right front SIH seat (N72/1s10) going out.

-----------------------------------------------------------------------------------------

The upper control panel control unit (N72/1) reads the signals of the left front SIH switch (N72/1s2) or the right front SIH switch (N72/1s10) and interrupts the power output, i.e. the circuit that heats up the hot wire, to the following heating elements:

Heated cushion, left front seat (R13/1)

Heated cushion, left front backrest (R13/2)

Heated cushion, right front seat (R13/3)

Heated cushion, right front backrest (R13/4)

Heating stage 2 of the SIH is switched to heating stage 1 automatically after t = 5 min.

-----------------------------------------------------------------------------------------

Automatic Off of the SIH after an aborted starting procedure

Function prerequisites:

Circuit 15R OFF

Circuit 15C ON

The upper control panel control unit (N72/1) interrupts the power output to the following heating elements. This is indicated by the LEDs in the left front SIH switch (N72/1s2) or right front SIH switch (N72/1s10) going out:

Heated cushion, left front seat (R13/1)

Heated cushion, left front backrest (R13/2)

Heated cushion, right front seat (R13/3)

Heated cushion, right front backrest (R13/4)

The time interval of heating stage 2 of the SIH is paused. If the status "Circuit 15R ON" is activated again within t = 30 s, the SIH is activated in the previously active heating stage without the need to actuate the left front SIH switch (N72/1s2) or right front SIH switch (N72/1s10) again.

-----------------------------------------------------------------------------------------

If the status "Circuit 15C OFF" is activated, the SIH is deactivated.

Automatic Off of the SIH during the starting procedure

Function requirements:

C. 15X OFF

The upper control panel control unit (N72/1) interrupts the power output to the following heating elements. The LEDs in the left front SIH switch (N72/1s2) or right front SIH switch (N72/1s10) remain lit:

Heated cushion, left front seat (R13/1)

Heated cushion, left front backrest (R13/2)

Heated cushion, right front seat (R13/3)

Heated cushion, right front backrest (R13/4)

If the upper control panel control unit (N72/1) detects the status "Circuit 15X ON", the SIH is activated in the previously active heating stage again with a delay of 2 s.

-----------------------------------------------------------------------------------------

Automatic Off of the SIH with unstable neutral

Function prerequisites:

Terminal 61 ON

Signal "Neutral unstable"

The upper control panel control unit (N72/1) interrupts the power output to the following heating elements. The LEDs in the left front SIH switch (N72/1s2) or right front SIH switch (N72/1s10) remain lit:

Heated cushion, left front seat (R13/1)

Heated cushion, left front backrest (R13/2)

Heated cushion, right front seat (R13/3)

Heated cushion, right front backrest (R13/4)

If the upper control panel control unit (N72/1) detects the signal "Neutral stable", the SIH is activated in the previously active heating stage again.

-----------------------------------------------------------------------------------------

Automatic switching off with battery voltage 11 V

Function prerequisites:

Circuit 15R ON

SIH activated

Undervoltage 11 V lasts longer than t = 3 s

The upper control panel control unit (N72/1) interrupts the power output to the following heating elements. This is indicated by the LEDs in the left front SIH switch (N72/1s2) or right front SIH switch (N72/1s10) flashing:

Heated cushion, left front seat (R13/1)

Heated cushion, left front backrest (R13/2)

Heated cushion, right front seat (R13/3)

Heated cushion, right front backrest (R13/4)

If the undervoltage 11 V lasts longer than t = 30 s, an error is stored in the upper control panel control unit (N72/1).

-----------------------------------------------------------------------------------------

If an overvoltage 15 V lasts longer than t = 3 s, the SIH is deactivated immediately. The LEDs in the left front SIH switch (N72/1s2) or right front SIH switch (N72/1s10) go out.

Upper control panel control unit (OBF), location/task/design

GF54.21-S-4300S

Heated cushion, location/task

GF91.30-S-3200S

Referenced documents