GF91.30-S-2001S | Switch off seat heater, function | 27.1.04 |
MODEL 639.601 /603 /605 /701 /703 /705 /711 /713 /811 /813 /815
with CODE (H16) Heater for driver seat
with CODE (H15) Heater for front passenger seat
Function requirements:
Circuit 15R ON
Heated seats (SIH) system is activated
No overvoltage or undervoltage
Heating stage 1 of the SIH system is deactivated by pressing the left front SIH switch (N72/1s2) or the right front SIH switch (N72/1s10) up again. This is indicated by the one light emitting diode (LED) in the left front SIH switch (N72/1s2) or the right front SIH seat (N72/1s10) going out.
Heating stage 2 of the SIH system is deactivated by pressing the left front SIH switch (N72/1s2) or the right front SIH switch (N72/1s10) down again. This is indicated by the 2 LEDs in the left front SIH switch (N72/1s2) or the right front SIH seat (N72/1s10) going out.
-----------------------------------------------------------------------------------------
The upper control panel control unit (N72/1) reads the signals of the left front SIH switch (N72/1s2) or the right front SIH switch (N72/1s10) and interrupts the power output, i.e. the circuit that heats up the hot wire, to the following heating elements:
Heated cushion, left front seat (R13/1)
Heated cushion, left front backrest (R13/2)
Heated cushion, right front seat (R13/3)
Heated cushion, right front backrest (R13/4)
Heating stage 2 of the SIH is switched to heating stage 1 automatically after t = 5 min.
-----------------------------------------------------------------------------------------
Automatic Off of the SIH after an aborted starting procedure
Function prerequisites:
Circuit 15R OFF
Circuit 15C ON
The upper control panel control unit (N72/1) interrupts the power output to the following heating elements. This is indicated by the LEDs in the left front SIH switch (N72/1s2) or right front SIH switch (N72/1s10) going out:
Heated cushion, left front seat (R13/1)
Heated cushion, left front backrest (R13/2)
Heated cushion, right front seat (R13/3)
Heated cushion, right front backrest (R13/4)
The time interval of heating stage 2 of the SIH is paused. If the status "Circuit 15R ON" is activated again within t = 30 s, the SIH is activated in the previously active heating stage without the need to actuate the left front SIH switch (N72/1s2) or right front SIH switch (N72/1s10) again.
-----------------------------------------------------------------------------------------
If the status "Circuit 15C OFF" is activated, the SIH is deactivated.
Automatic Off of the SIH during the starting procedure
Function requirements:
C. 15X OFF
The upper control panel control unit (N72/1) interrupts the power output to the following heating elements. The LEDs in the left front SIH switch (N72/1s2) or right front SIH switch (N72/1s10) remain lit:
Heated cushion, left front seat (R13/1)
Heated cushion, left front backrest (R13/2)
Heated cushion, right front seat (R13/3)
Heated cushion, right front backrest (R13/4)
If the upper control panel control unit (N72/1) detects the status "Circuit 15X ON", the SIH is activated in the previously active heating stage again with a delay of 2 s.
-----------------------------------------------------------------------------------------
Automatic Off of the SIH with unstable neutral
Function prerequisites:
Terminal 61 ON
Signal "Neutral unstable"
The upper control panel control unit (N72/1) interrupts the power output to the following heating elements. The LEDs in the left front SIH switch (N72/1s2) or right front SIH switch (N72/1s10) remain lit:
Heated cushion, left front seat (R13/1)
Heated cushion, left front backrest (R13/2)
Heated cushion, right front seat (R13/3)
Heated cushion, right front backrest (R13/4)
If the upper control panel control unit (N72/1) detects the signal "Neutral stable", the SIH is activated in the previously active heating stage again.
-----------------------------------------------------------------------------------------
Automatic switching off with battery voltage 11 V
Function prerequisites:
Circuit 15R ON
SIH activated
Undervoltage 11 V lasts longer than t = 3 s
The upper control panel control unit (N72/1) interrupts the power output to the following heating elements. This is indicated by the LEDs in the left front SIH switch (N72/1s2) or right front SIH switch (N72/1s10) flashing:
Heated cushion, left front seat (R13/1)
Heated cushion, left front backrest (R13/2)
Heated cushion, right front seat (R13/3)
Heated cushion, right front backrest (R13/4)
If the undervoltage 11 V lasts longer than t = 30 s, an error is stored in the upper control panel control unit (N72/1).
-----------------------------------------------------------------------------------------
If an overvoltage 15 V lasts longer than t = 3 s, the SIH is deactivated immediately. The LEDs in the left front SIH switch (N72/1s2) or right front SIH switch (N72/1s10) go out.