gf8330p2000b

Tempmatic air conditioning pushbutton control module position/function

Type gf · topic 83.30 · version 0103 · 2000-01-26

Applies to: MODEL 202 up to 31.8.95 with CODE (580) Air conditioning or Tempmatic for USA

Where it sits

Function group 3 Body › 83 Climate control › 83.30 Air conditioning — Series 202

GF83.30-P-2000B

Tempmatic air conditioning pushbutton control module position/function

12.12.97

MODEL 202 up to 31.8.95 with CODE (580) Air conditioning or Tempmatic for USA

Tempmatic air conditioning pushbutton control module position/function

P83.30-2040-11

1 Temperature selection wheels

2 Blower switch

3 Air distribution switch

Recirculated air pushbutton

EC push button

Rest pushbutton

Reheat pushbutton

N19/1 Tempmatic (Tempmatic A/C) control and operating module

Function

The control and operating module (N19/1) of the Tempmatic (Tempmatic A/C) permits performance of adjustments required by the driver, such as:

Temperature by using the temperature selection wheels (1)

Air quantity by using the blower switch (2)

Air distribution by using the air distribution switch (3)

Recirculated air by pressing the recirculated air pushbutton
( )

Activation of residual engine heat recirculation, with ignition off, by pressing the Rest pushbutton

( )

Switching off the cooling by pressing the EC pushbutton ()

Air drying operation by pressing the reheat pushbutton

( )

Furthermore the control module integrated into the control and operating (N19/1) module takes over regulation and control of systems, such as:

comparison of the preselected / actual temperatures and adjustment of the air output temperature to the air outlets

automatic switching from fresh air to recirculated air

electrical actuation of the refrigerant compressor

actuation of the auxiliary ventilator

The control and operation module (N19/1) can be diagnosed so that faults arising are stored in a fault memory, which can be read out with the aid of the HHT.

When changing the control and operating module (N19/1) a variant coding should be performed with the aid of the Hand-Held Tester or DMNL air conditioning.

In the new control and operating module an outside temperature of < 15 °C can be stored, so that when the air conditioning system is switched on ( does not light up) no cooling takes place. The air conditioning only functions following a test drive, because then with a speed signal of > 20 km/h the stored outside temperature value < 15 °C is overwritten by the actual value.

Blower switch Location/task/function

GF83.25-P-2104A

Air distribution switch Location/task/function

GF83.25-P-2103A

Temperature selection wheel Location/task/function

GF83.25-P-2105A

Recirculated air pushbutton Location/task/function

GF83.40-P-2145A

EC pushbutton Location/task/function

GF83.40-P-2146E

Reheat pushbutton Location/task/function

GF83.40-P-2165E

Rest pushbutton Location/task/function

GF83.40-P-2148A

Referenced documents