Y127/1 Oil spray nozzles valve
The oil spray nozzles valve is located on the left crankcase.
D18.30-1111-03
Task
The oil spray nozzles valve controls the oil feed to the oil spray nozzles.
Input signals
Direct input signals
The oil spray nozzles valve receives voltage signals from the CDI control unit (N3/28).
In a de-energized condition the oil spray nozzles valve is open.
The oil spray nozzles are activated in the post-start phase if one of the following conditions is met:
- Engine oil temperature > -10°C
- The max. shutoff time (depending on the model, engine power, intake air temperature and engine oil temperature) is not reached
- The engine speed or injection quantity has not reached an established limit value
At high engine oil temperatures, activation of the oil spray nozzles can be interrupted depending on the engine speed.