gf0900p2000d

Turbocharging - function

Type gf · topic 09.00 · version 0102 · 2008-03-17

Applies to: ENGINE 271.942 in MODEL 203 up to Model Year 8 ENGINE 271.942 in MODEL 209

Where it sits

Function group 1 Engine › 09 Air intake, turbocharging › 09.00 General — Series 203 · Series 209

Also applies to engines/gearboxes: 271 942

GF09.00-P-2000D

Turbocharging - function

26.1.05

ENGINE 271.942 in MODEL 203 up to Model Year 8

ENGINE 271.942 in MODEL 209

Turbocharging - function

P09.00-2026-76

50 Compressor

50/1 Pressure damper (charge air)

110/1 Suction pipe

110/2 Charge air cooler

110/6 Charge air line

122 Suction damper (intake air)

B2/5 Hot film MAF sensor

M16/6 Throttle valve actuator

M16/7 Air recirculation flap actuator

Turbocharging - function

P09.50-2046-82

Maximum boost pressure

50 Compressor

50/1 Pressure damper (charge air)

50/2 Recirculated air line

110/1 Suction pipe

110/2 Charge air cooler

110/6 Charge air line

122 Suction damper (intake air)

M16/7 Air recirculation flap actuator

a Recirculated air flap closed

The supercharger is permanently driven over a poly-V-belt by the crankshaft.

The charge pressure is controlled by the recirculated air flap actuator which is located at the intake/recirculated air opening of the supercharger.

If the air recirculation flap is closed, the engine will have the full boost pressure made available to it.

The recirculated air flap is always closed at full load.

Turbocharging - function

P09.50-2045-82

Regulated boost pressure

50 Compressor

50/1 Pressure damper (charge air)

50/2 Recirculated air line

110/1 Suction pipe

110/2 Charge air cooler

110/6 Charge air line

122 Suction damper (intake air)

M16/7 Air recirculation flap actuator

b Recirculated air flap open

If the recirculated air flap is opened, the boost pressure air is guided back via the recirculated air line to the compressor.

The air recirculation flap can be adjusted continuously from 0 to 90° and can regulate the boost pressure over the recirculated air line.

ME-SFI control unit - location/task/design/function

N3/10

GF07.61-P-5000KE

Charge pressure cooler - location/task/design/function

110/2

GF09.41-P-3100KE

Recirculated air flap actuator - location/task/design/function

M16/7

GF09.50-P-3101KE

Supercharger - location/task/design/function

50

GF09.50-P-3102KE

Referenced documents