AR07.54-D-0001A | Leaktightness test for natural gas system | 8.7.98 |
ENGINE 111.979 in MODEL 902.061 /062, 903.061 /062 /063, 904.062 /063
with CODE (KL8) Pressurized gas reservoir in cargo area
with CODE (MS7) NGT (Natural Gas Transporter) sprinter
ENGINE 111.979 in MODEL 902.012 /062 /072, 903.012 /013 /022 /062 /063 /072 /073, 904.012 /013 /062
with CODE (KL9) Compressed gas tank underfloor arrangement
with CODE (MS7) NGT (Natural Gas Transporter) sprinter
ENGINE 111.984 in MODEL 902.661 /662, 903.661 /662 /663, 904.662 /663
with CODE (KL8) Compressed gas tank in cargo area
with CODE (MS7) NGT (Natural Gas Transporter) sprinter
ENGINE 111.984 in MODEL 902.612 /662 /672, 903.612 /613 /622 /662 /663 /672 /673, 904.612 /613 /662
with CODE (KL9) Compressed gas tank underfloor arrangement
with CODE (MS7) NGT (Natural Gas Transporter) sprinter
D07.54-0009-09
Illustration shows underfloor position KL9,
as for cargo area position KL8
1 Threaded connections at rear compressed gas tanks
5 Threaded connections at pressure regulator
6 Threaded connections at gas filter
7 Threaded connections at gas distribution rail
8 Threaded connections at gas pressure gauge
2 Threaded connections at front compressed gas tanks
3 Threaded connections at distributor block
4 Threaded connections at check valve
| Checking | ||
Danger! | Risk of explosion due to escaping gas or overheating of compressed gas tank, while working on natural-gas vehicles. Risk of frostbite to exposed body parts from escaping natural gas or contact with components near the valves, while draining compressed gas tanks. Risk of poisoning or suffocation if natural gas is inhaled. | Remove any sources of ignition. Ensure that the work area is adequately ventilated. Wear heat-protective gloves. | |
1 | Coat the inspection points shown (1 - 8) with soap suds and check for bubbles | To check the rear threaded connection at the check valve (4), the vehicle must be briefly refueled with natural gas. | |
2 | Record the result in the test log |
Referenced documents
- ar0754d000101a Test log leak test natural gas system
- as0000z001801a Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves