Engine | 611, 612 (except 612.990) in model 203 |
with code 580 (Air-conditioning system) | |
Engine | 611, 612 (except 612.990) in model 203 |
with code 581 (Automatic air conditioning) | |
Engine | 612 in model 209 |
with code 580 (Air-conditioning system) | |
Engine | 612 in model 209 |
with code 581 (Automatic air conditioning) |
P83.55-2116-09
Shown on model 203.0 |
1 | Bolts | 3 | Connector | 11 | Suction pressure line | ||
2 | Screw | 10 | High pressure pipe | A9 | Refrigerant compressor | ||
2a | Bolts |
| Remove/install | ||
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
1 | Remove receiver drier |
| |
Model 203 as of 24.04.04 | |||
Installation: The receiver drier must be replaced every time the refrigerant circuit is opened, in order to guarantee correct operation of the air conditioning system. | |||
2 | Remove poly-V-belt | ||
3 | Disconnect connector coupling (3) | ||
4 | Remove bolt (1) | Screw/bolt, suction line to refrigerant compressor | |
Screw/bolt, pressure line to A/C compressor | |||
5 | Remove suction pressure line (11) and high-pressure line (10) and place to one side | Seal openings of suction pressure line (11) and high-pressure line (10) to prevent foreign objects entering. | |
Installation: Install new sealing rings. Moisten thread and sealing rings with compressor oil. | |||
Record plug | |||
6 | Remove screw/bolt (2) | Screw, refrigerant compressor to bracket | |
7 | Remove bottom section of soundproofing | ||
8 | Remove bolt (2a) | Screw, refrigerant compressor to bracket | |
9 | Remove refrigerant compressor (A9) | Remove refrigerant compressor (A9) upwards. | |
10 | Install in the reverse order | ||
11 | Correct oil level in refrigerant compressor (A9) | ||
Replace | |||
12 | Replace suction pressure line (11) and high-pressure lines (10) with sealing rings | Only if the refrigerant compressor (A9) is replaced as a result of internal damage. | |
13 | Replace expansion valve |
| |
MODEL 209 | |||
Only if the refrigerant compressor (A9) is replaced as a result of internal damage. |
129 589 00 91 00
Record plug
Henviste dokumenter
- ah8330n000301a Oplysninger om håndtering af kølemidlet R134a
- ah8330n000401a Fremgangsmåde ved beskadiget eller utæt klimaanlæg
- ah8330n000501a Klimaanlæggets kredsløb og komponenter skal beskyttes mod fugt ved reparationer
- ar1322p1202hb
- ar8330p5520p
- ar8330p5520p
- ar8330p5520q
- ar8330p6521p
- ar8330p6521p
- ar8330p6521pa
- ar8330p6521pa
- ar8355p5250p
- ar8355p5250p Korrektion af oliestand i klimaanlæg ved udskiftning af kølekompressor
- ar9430p5300p
- as8300z000101a Fare for eksplosion ved svejse- og loddearbejde på det lukkede klimaanlæg. Fare for forgiftning ved indånding af overophedet kølemiddeldamp. Fare for personskade ved hud- og øjenkontakt med flydende kølemiddel