ar8330s1760a

Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks

Type ar · emne 83.30 · version 0122 · 2011-11-28

Gælder for: MODEL 638.0 /1 /2 with CODE (H06) Air conditioning with CODE (HH7) Air conditioning in rear

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 83 Klimatisering › 83.30 Klimaanlæg — Serie 638 (modeller 0**, 1**, 2**)

EinPAS 39 Varmesystem/ventilation/køling › 39.15 Klimatisering › 39.15.5 Klimaanlæg komplet — Serie 638 (modeller 0**, 1**, 2**)

AR83.30-S-1760A

Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks

15.11.11

MODEL 638.0 /1 /2
with CODE (H06) Air conditioning
with CODE (HH7) Air conditioning in rear

Drain, evacuate and recharge air conditioning, check for proper operation and   
	check for leaks

S83.30-2035-06

1 Charging equipment

1.1 Manometer battery

1.2 Connector (red)

1.3 Connector (blue)

2 Suction pipe

3 High pressure pipe

Danger!

Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained.

AS83.00-Z-0001-01A

1

Connect charging equipment (1) with connector (blue) (1.3) to Schrader valve of high-pressure line (3) and with connector (red) (1.2) to Schrader valve of suction line (2)

Attach manometer battery (1.1) at an appropriate location.

All operation steps must be performed in accordance with the operating instructions for the respective charging equipment.

Air conditioner service unit R134a

gotis://E_83_05.0

2

Drain air conditioning system

3

Drain separated oil for refrigerant compressor from inspection glass of charging equipment and determine exact quantity

Drained quantity must be replaced with fresh oil for refrigerant compressor

4

Clean and evacuate air conditioning system

5

Supplement oil for refrigerant compressor

The exact quantity determined when drained must be used.

6

Charge air conditioning system

*BF83.30-N-1009-01A

7

Check air conditioning system for leaks with leak detector

Air conditioner service unit R134a

gotis://E_83_05.0

Danger!

Risk of accident caused by vehicle starting off by itself when engine is running. Risk of injury caused by crush injuries and burns if you place your hand into the engine when it is started or when it is running

Secure vehicle to prevent it from moving by itself.
Wear closed and snug-fitting work clothes.
Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

8

Check air conditioning for proper operation

Run engine at idling speed for about 4 minutes and check all the component functions which are of relevance for proper operation of the air conditioning system.

Air conditioning

Number

Designation

Model
638 with compressor 7SB16

Model
638 with compressor 10PA17C

BF83.30-N-1009-01A

Total filling capacity, refrigerant

kg

0,850

0,920

Specifications for
Operating Fluids

Sheet

BB00.40-P-0361-00A

BB00.40-P-0361-00A

Air conditioning

Number

Designation

Model
638 with compressor SD7V16

Model
638 with compressor 7SB16 and code HH7

BF83.30-N-1009-01A

Total filling capacity, refrigerant

kg

0,850

1,100

Specifications for
Operating Fluids

Sheet

BB00.40-P-0362-00A

BB00.40-P-0361-00A

Henviste dokumenter