Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
| Remove | ||
1 | Remove battery to be checked. | Remove on-board electrical system battery | |
Remove the auxiliary batteryModel 447 | |||
Remove additional battery for emergency shift park pawlModel 447 with engine 780.701 | |||
Remove additional battery for ECO start/stop functionModel 447 | |||
Remove additional battery for ECO start/stop functionModel 447 | |||
| Check | ||
2 | Check battery for external leakages or damage via visual check. | If a leakage or any damage is detected, | |
| |||
replace battery and dispose of properly and in environmentally-compatible manner. | |||
3 | Check on-board electrical system battery using battery test device. | When checking the on-board electrical system battery. | |
| 000 588 02 19 00 Battery tester | ||
4 | Check auxiliary battery using battery test device. | Model 447 | |
| 000 588 02 19 00 Battery tester | ||
5 | Check auxiliary battery for ECO start/stop function using battery test device. | Model 447 | |
| 000 588 02 19 00 Battery tester | ||
6 | Check auxiliary battery for park pawl emergency shift mode. | When checking the auxiliary battery for park pawl emergency shift mode. | |
| Service Information: Testing method for additional battery for park pawl emergency shift mode | Model 447 with engine 780 | |
7 | Reduce increased voltage of on-board electrical system battery after charging process. | When checking the on-board electrical system battery, if the message "Surface voltage detected" is shown on the battery test device display. | |
| 000 588 03 19 00 Load tester | ||
8 | Reduce increased voltage of auxiliary battery after charging process. | Model 447 | |
| 000 588 03 19 00 Load tester | ||
9 | Reduce increased voltage of auxiliary battery for ECO start/stop function after charging process. | Model 447 | |
| 000 588 03 19 00 Load tester | ||
10 | Check on-board electrical system battery again using battery test device. | When checking the on-board electrical system battery, if an increased voltage was reduced after the charging process. | |
| 000 588 02 19 00 Battery tester | ||
11 | Check auxiliary battery again using battery test device. | Model 447 | |
| 000 588 02 19 00 Battery tester | ||
12 | Check auxiliary battery for ECO start/stop function again using battery test device. | Model 447 | |
| 000 588 02 19 00 Battery tester | ||
13 | Charge on-board electrical system battery. | When checking the on-board electrical system battery, if the "Charge and check" message is shown on the battery test device display. | |
14 | Charge auxiliary battery. | Model 447 | |
15 | Charge auxiliary battery for ECO start/stop function. | Model 447 | |
16 | Fill out test sheet. | ||
| Test sheet for on-board electrical system batteries, starter batteries and support batteries, form | ||
| Install | ||
17 | Install battery. | Install on-board electrical system battery | |
Install additional batteryModel 447 | |||
Install additional battery for emergency shift park pawlModel 447 with engine 780.701 | |||
Install additional battery for ECO start/stop functionModel 447 | |||
Install additional battery for ECO start/stop functionModel 447 | |||
The batteries must never be mixed up. |
Henviste dokumenter
- ah5410p000101a
- ah5410p000101a Oplysninger om batterier
- ar5410s0005e
- ar5410s0005e
- ar5410s0007e
- ar5410s0111e
- ar5410s0111ee
- ar5410s0120e
- ar5410s112901e
- ar5410s112903e
- ar5410s1130e
- as5410z000101a Brand-/eksplosionsfare på grund af kortslutning og udsivende knaldgas. Forbrændingsfare/fare for personskade ved ætsning af øjne, hud og sliminder på grund af batterielektrolyt/-tåge, kortslutning og lysbuepåvirkning. Fare for
- of5410p300002b
- si5410s0050a
- ws1500p0027b
- ws5400n3006b