ar5410s112903e

Reduce increased voltage after charging process

Type ar · emne 54.10 · version 0102 · 2015-12-22

Gælder for: Model 447, 448

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 2 Chassis › 54 El-system, udrustning og instrumenter › 54.10 Batteri, spændingsforsyning, spændingstransformer — Serie 447 · Serie 448

EinPAS 25 bilens ledningsnet/netværk/multifunktion › 25.20 Køretøjets ledningsnet › 25.20.1 Grundinformation — Serie 447 · Serie 448

AR54.10-S-1129-03E

Reduce increased voltage after charging process

000 588 03 19 00 Load tester

WS15.00-P-0027B

Model

447, 448

Requirements:

Battery is removed or disconnected from on-board electrical system.

During the preceding battery test, a "Surface voltage detected" message appears in the battery tester/test equipment display.

Reduce increased voltage after charging process

1

Disconnect battery tester.



2

Set rotary knob (3) on load tester (1) to 16 V and rotary knob (4) to 50 A.



3

Clip load pliers (5) onto the battery.



4

Connect terminals (7) to corresponding load clamps (5).



5

Position current clamp (6) around battery positive line.


Pay attention to current direction. Measurement conducted using an inductive coil in the current clamp (6).



6

Switch on load tester (1) using operating lever (2) and apply a load of 20 A to 30 A to battery for approx. 60 s.


The increased voltage is now reduced.


P54.10-2698-11