Verwendung in FG 15/Satz B |
|
000 588 03 19 00
Note:
These testers are not approved by Mercedes-Benz for obtaining findings on the starter battery.
Minimum requirements:
The load tester is suitable for a direct voltage of up to 30 V.
The load allows itself to be set steplessly or in steps of a maximum of 0.5 kW.
The engageable load is at least 2.1 kW for a duty cycle of at least 15 seconds.
The flow of current is interrupted during clamping on and disconnecting the tester on the on-board electrical system.
The usual designations for volt amp(s) tester on the free market include: load tester, Carbon Pile Load, battery tester or electronic load.