ws1500p0027b

000 588 03 19 00 Load tester

Type ws · emne 15.00 · version 0101 · 2015-06-29

Gælder for: Model all

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 15 El-system motor › 15.00 Generelt — Serie 900 (modeller 9**) · Serie 902 (modeller 9**) · Serie 904 (modeller 918, 919, 924, 925, 938, 943, 957) · Serie 906 (modeller 917, 918, 924, 953)

EinPAS 25 bilens ledningsnet/netværk/multifunktion › 25.20 Køretøjets ledningsnet › 25.20.1 Grundinformation — Serie 900 (modeller 9**) · Serie 902 (modeller 9**) · Serie 904 (modeller 918, 919, 924, 925, 938, 943, 957) · Serie 906 (modeller 917, 918, 924, 953)

Gælder også for motorer/gearkasser: 139 ***, 254 ***, 256 ***, 272 ***, 276 ***, 282 ***, 457 9**, 541 9**, 542 9**, 608 ***, 700 4**, 700 420, 700 421, 700 422, 700 423, 715 3**, 715 5**, 722 6**, 722 9**, 724 ***, 724 0**, 724 033, 724 044, 724 045, 724 1**, 724 103, 724 114, 724 115, 724 120, 725 ***, 725 0**, 725 035, 725 037, 725 038, 725 085, 725 1**, 739 390, 739 391, 739 395, 739 396, 739 397, 739 398, 739 399, 740 698, 743 3**, 743 4**, 743 498, 746 971, 924 9**, 924 910, 925 9**, 926 9**

WS15.00-P-0027B

000 588 03 19 00 Load tester

29.6.15

Model

all

000 588 03 19 00 Load tester

Verwendung in FG 15/Satz B


Purpose:
Load tester for loading the vehicle on-board network for the alternator charge current checking.
Test equipment category CAT_B.
Procurement information:
This criteria catalogue serves to provide support for selection of variants of workshop equipment available on the free market. It just describes the minimum requirement for fulfilling the Mercedes-Benz standard. There is therefore no reference made to manufacturer specific equipment or devices.

000 588 03 19 00

Note:

These testers are not approved by Mercedes-Benz for obtaining findings on the starter battery.

Minimum requirements:

The load tester is suitable for a direct voltage of up to 30 V.

The load allows itself to be set steplessly or in steps of a maximum of 0.5 kW.

The engageable load is at least 2.1 kW for a duty cycle of at least 15 seconds.

The flow of current is interrupted during clamping on and disconnecting the tester on the on-board electrical system.

The usual designations for volt amp(s) tester on the free market include: load tester, Carbon Pile Load, battery tester or electronic load.