Shown on model 447 with code E28 (Additional battery for retrofitted consumers) |
1 | Ground cable |
2 | Bolts |
3 | Bracket |
7 | Vent hose |
G1/1 | Additional battery |
S54.10-4617-11
Shown on model 447 with code EE8 (Battery 12V 100 Ah) |
1 | Ground cable |
2 | Bolts |
3 | Bracket |
4 | Nut |
5 | Ground cable |
6 | Carrier plate |
G1/1 | Additional battery |
S54.10-4672-06
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
| Remove/install | ||
1 | Disconnect ground line (1) of additional battery (G1/1) | ||
2 | Remove screws (2) | ||
3 | Remove bracket (3) | ||
4 | Detach vent hose (7) from additional battery (G1/1) | Model 447 | |
Installation: | |||
5 | Place carrier plate (6) to one side so that additional battery (G1/1) can be pulled out of seat base | Model 447.7/8 | |
6 | Pull additional battery (G1/1) out of seat base until positive terminal is accessible | ||
7 | Remove positive terminal cover | ||
8 | Disconnect positive line from additional battery (G1/1) | Bolt, positive line to positive terminal of on-board electrical system battery/additional battery | |
9 | Remove additional battery (G1/1) from seat base | ||
10 | Detach ground line (1) from negative terminal of additional battery (G1/1) | Model 447 | |
Bolt, ground line to negative terminal for on-board electrical system battery/additional battery | |||
11 | Install in the reverse order |
Henviste dokumenter
- ah5410p000101a Oplysninger om batterier
- ah5410p000101a
- ar5410s0004e
- as5410z000101a Brand-/eksplosionsfare på grund af kortslutning og udsivende knaldgas. Forbrændingsfare/fare for personskade ved ætsning af øjne, hud og sliminder på grund af batterielektrolyt/-tåge, kortslutning og lysbuepåvirkning. Fare for