ar3222p8100lf

Check AIRmatic for leaks.

Type ar · emne 32.22 · version 0105 · 2016-08-19

Gælder for: Model 217 except code 487 (Active Body Control (ABC)) Model 222 except code 487 (Active Body Control (ABC))

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 2 Chassis › 32 Affjedring › 32.22 Luftaffjedring — Serie 217 · Serie 222

EinPAS 20 Undervogn › 20.16 affjedring › 20.16.1 Grundinformation — Serie 217 · Serie 222

AR32.22-P-8100LF

Check AIRmatic for leaks.

16.08.2016

Model

217

except code 487 (Active Body Control (ABC))

Model

222

except code 487 (Active Body Control (ABC))

Check AIRmatic for leaks.

P32.22-2552-09

Shown on MODEL 222.082 without pressure reservoir

10

Right front suspension strut

13

Left rear suspension strut

Y36/6

AIRMATIC valve unit

11

Left front suspension strut

A9/1

AIRMATIC compressor

12

Right rear suspension strut

N51/3

AIRMATIC control unit

Check AIRmatic for leaks.

Shown on vehicle with pressure reservoir

A

Pressure reservoir

P32.22-2516-05

Check AIRmatic for leaks.

Shown on MODEL 222.082

A9/1

AIRMATIC compressor

A9/1y1

AIRMATIC pressure reduction valve

Y36/6

AIRMATIC valve unit

Y36/6b1

AIRMATIC pressure sensor

Y36/6y1

Left front level control valve

Y36/6y2

Right front level control valve

Y36/6y3

Left rear level control valve

Y36/6y4

Right rear level valve

Y36/6y5

AIRMATIC central reservoir filling valve

P32.31-2088-06

Notes on AIRmatic

AH32.22-P-1000-02LF

Remove/install

1

Remove front engine compartment paneling

AR61.20-P-1105LF

2

Remove left front fender liner

AR88.10-P-1300LF

3

Expose pressure line connections on rear suspension struts (12, 13)


Model 222
with code Z07 (Top protection)
except code 487 (Active Body Control (ABC))

AR32.25-P-1016LFS

Model 217
except code 487 (Active Body Control (ABC))
Model 222
except code 487 (Active Body Control (ABC))
except code Z07 (Top protection)

AR32.25-P-1016LFB

Check

4

Spray pressure line connections on suspension struts (10, 11, 12,13) with leak detection spray

Wait for roughly 10 to 15 minutes after spraying the compressed-air lines. This allows smaller leaks to be detected (bubbles form). Larger leaks are visible immediately.

Leak detection spray

*BR00.45-Z-1002-03A

5

Spray top and bottom of dust boots on suspension struts (10, 11, 12, 13) with leak detection spray

After spraying the top and bottom of the dust boots on the suspension struts, wait approx. 10 to 15 min. This allows smaller leaks to be detected (bubbles form). Larger leaks are visible immediately.

Leak detection spray

*BR00.45-Z-1002-03A

6

Spray leak detection spray onto the pressure line connections on AIRmatic valve unit (Y36/6) and AIRMATIC compressor (A9/1)

Wait for roughly 10 to 15 minutes after spraying the compressed-air lines. This allows smaller leaks to be detected (bubbles form). Larger leaks are visible immediately.

Leak detection spray

*BR00.45-Z-1002-03A

7

Spray leak detection spray onto the pressure line connections on the pressure reservoir (A) (if installed)

Wait for roughly 10 to 15 minutes after spraying the compressed-air lines. This allows smaller leaks to be detected (bubbles form). Larger leaks are visible immediately.

Leak detection spray

*BR00.45-Z-1002-03A

8

Cover rear shelf or trim in area of pressure line connections with clean rags

Socket wrench bit

*211589000900

Knife

*000589122800

If pressure line connections are defective

Repair AIRmatic pressure line connection


AR32.22-P-2001-02SX

9

Install in the reverse order

Check AIRmatic for leaks.
Check AIRmatic for leaks.

000 589 12 28 00

Knife

211 589 00 09 00

Socket wrench bit

Repair materials

Number

Designation

Order number

BR00.45-Z-1002-03A

Leak detection spray

Christof Fischer GmbH
www.kaeltefischer.de

Henviste dokumenter