ar0941s6936ce

Remove/install low-temperature circuit cooler

Type ar · emne 09.41 · version 0101 · 2019-10-14

Gælder for: Engine 608 in model 415

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 09 Luftindsugning, luftladning › 09.41 Ladeluftrør/ladeluftkøling — Serie 415

EinPAS 15 Motor › 15.25 Motorkølesystem › 15.25.31 Motorkøler — Serie 415

Gælder også for motorer/gearkasser: 608 ***

AR09.41-S-6936CE

Remove/install low-temperature circuit cooler

10.10.2019

Engine

608 in model 415

Remove/install low-temperature circuit cooler

S09.41-A012-79

Shown with code H06 (A/C)

1

Radiator low-temperature circuit

3

Coolant line

4

Lock

2

Coolant line

Danger

Risk of death caused by vehicle slipping or toppling off of the lifting platform.

Align vehicle between vehicle lift columns and position the four support plates at the vehicle lift support points specified by the vehicle manufacturer.

AS00.00-Z-0010-01A

Warning

Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant.

Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers.
Wear protective gloves, protective clothing and safety glasses.

AS20.00-Z-0001-01A

Topical note

Notes on coolant

AH20.00-N-2080-01A

Notes on coolant level

AH20.00-P-1142-01CW

Remove/install

1

Drain coolant out of the low-temperature circuit cooler (1).

AR20.00-S-1142CE

In this case, the coolant line (2) is already removed.

Removal: Do not attach coolant line (2) again.

2

Remove front crossmember.

AR62.30-S-1360C

3

Remove air supply ducting from cooler.

AR20.20-S-6823C

4

Remove air duct segment on cooler.

AR20.20-S-3865-10CD

5

Remove condenser from the low-temperature circuit cooler (1).


Model 415 with code H06 (air conditioning), model 415 with code HH9 (semi-automatic regulated air conditioning, TEMPMATIC)

AR83.30-S-6540C

Do not suction off refrigerant; do not remove refrigerant lines. Swivel condenser to the side and fasten outside of the working area.

6

Remove coolant line (3).

AR20.20-P-7441-01RQ

Seal coolant lines (2, 3). Collect coolant which flows out.

Commercially available devices/tools
Collecting pan

Set of protective covers

*001589019100

7

Remove low-temperature circuit cooler (1) upward.

To do so, release the locks (4).

8

Install in the reverse order.

Remove/install low-temperature circuit cooler

001 589 01 91 00

Set of protective covers

Henviste dokumenter