AD83.70-P-5002A | Heater booster (ZUH) diagnosis, troubleshooting | 13.8.97 |
MODEL 168 with ENGINE 668.940
with heater booster
MODEL 202 with ENGINE 611.960
with heater booster
MODEL 210 as of 1.9.96 with ENGINE 602.982
with heater booster
MODEL 210 with ENGINE 611.961
with heater booster
Danger! | Risk of explosion due to fuel vapors, risk of poisoning from inhaling combustion gases and risk of injury from burns during or after heater operation. | Do not put stationary heater/auxiliary heater or engine with heater booster into operation in confined spaces or while refuelling. Allow heater unit to cool down after operation and wear safety gloves. | |
Heater booster (ZUH) diagnosis, advanced information | |||
Stationary heater/heater booster unit, location of components | Model 210 up to 31.05.98 Model 202 Model 210 as of 01.06.98 Model 168 | ||
Troubleshooting | |||
Complaint | Possible cause | Note | Remedy |
Stationary heater/heater booster unit (A6) does not start Coolant temperature < 68°C Outside temperature < 5°C | Cut-in signal from generator (G2) ECT switch (S25/17) Air temperature switch (S25/18) Stationary heater/heater booster control module (A6n1) | Model 210 as of 01.09.96 up to 28.02.97 |
Check all actual values with HHT |
Stationary heater/heater booster unit (A6) does not start Coolant temperature < 73°C Outside temperature < 8°C | Cut-in signal from instrument cluster (A1) Cut-in signal from CDI control module (N3/9) | Model 210 as of 01.03.97 and model 202 Model 168 | |
Malfunction shut-down at start of heater boost operation with heater unit run-on (approx. 120 seconds) of combustion air blower (A6m2) without repeat start. | Glow pin (A6r2) in its flame monitor function Stationary heater/heater booster control module (A6n1) | Check all actual values with HHT | |
Combustion starts during the preglow time | Remains of fuel in combustion chamber due to unsuccessful attempts at starting Internal leakage in stationary heater fuel metering pump (Y23) | Allow heater unit to operate for 10 minutes | |
Stationary heater/heater booster unit (A6) does not increase heat output after combustion stabilizes | Combustion air blower (A6m2) Stationary heater fuel metering pump (Y23) Stationary heater/heater booster control module (A6n1) | Check all actual values with HHT | |
Heat output too low | Combustion air inlet on stationary heater/heater booster unit (A6) Routing of coolant lines Stationary heater/heater booster control module (A6n1) | Check combustion air inlet for contamination and clean if necessary Check coolant lines for pinching and kinks and rectify if necessary. Check all actual values with HHT | |
Escape of combustion exhaust gases which are sooty or form dense smoke. | Combustion air inlet on stationary heater/heater booster unit (A6) Exhaust emissions value too high Fuel delivery quantity Combustion air blower (A6m2) Stationary heater/heater booster control module (A6n1) | Check combustion air inlet for contamination and clean if necessary Check and adjust exhaust emissions value with HHT Model 210 up to 28.02.97: Models 202, 210 as of 01.03.97: Model 168: Check all actual values with HHT | |
Grey/white combustion exhaust gases (white smoke) | Exhaust emissions value too low | Check and adjust exhaust emissions value with HHT | |
Loss of coolant Grey/white combustion exhaust gases (white smoke) Exhaust gas odor extremely sweet | Stationary heater/heater booster unit (A6) | Check heater booster unit for external leaks and replace heater unit if necessary. | |
Loss of fuel or fuel odor | Leaks in fuel supply to heater booster unit | Determine leakage point, check stationary heater fuel metering pump, fuel supply lines, connections and stationary heater/heater booster unit for fuel leaks and if necessary seal leakage point or replace component | |
It is not possible to test the heater booster components with the HHT No communication between HHT and stationary heater/heater booster control module (A6n1) | Cables, connections Voltage supply Diagnostic cable | Check and replace if necessary |
Henviste dokumenter
- ad8370p2002a
- ad8370p600102a
- ad8370p600201a
- ad8370p600202a
- ad8370p600202b
- ad8370p600202c
- ad8370p600203a
- ad8370p600204a
- ad8370p700002a
- ad8370p700101a
- ad8370p700101b
- ad8370p700101c
- as8370z000201a Fare for eksplosion på grund af brændstofdampe, fare for forgiftning ved indånding af forbrændingsgas og fare for personskade på grund af forbrændinger, under eller efter at varmesystemet har været i drift.
- gf8370p000203a
- gf8370p000203b
- gf8370p000203c
- gf8370p000203gc