gf8340p3000kn

Component description for automatic air conditioning control and operating unit

Typ gf · téma 83.40 · verze 0104 · 2015-03-25

Platí pro: MODEL 117, 156, 176, 242, 246

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.40 Automatická klimatizace — Řada 117 · Řada 156 · Řada 176 · Řada 242 · Řada 246

GF83.40-P-3000KN

Component description for automatic air conditioning control and operating unit

11.3.15

MODEL

117, 156, 176, 242, 246

Component description for automatic air conditioning control and operating unit

Model 117, 156, 176, 242 (except 242.890), 246 except CODE 581 (Automatic air conditioning)

N22/7

Automatic air conditioning control and operating unit

P83.40-4478-04

Control element

Controllable function

Operating feedback

Rear window heater button (N22/7s1)

Rear window heater ON/OFF

Integrated LED

Air recirculation mode button (N22/7s2)

Air recirculation mode ON/OFF

Integrated LED

Defrosting button (1)

Defrost mode ON/OFF

Integrated LED

"A/C" button (2)

Refrigerant compressor ON/OFF

Integrated LED

Temperature selector wheel (3)

Setting of specified temperature

LED on circumference of selector wheel

Air volume selector wheel (4)

Nominal air volume setting

LED on circumference of selector wheel

Windshield air distribution button (5)

Windshield air distribution On/Off

Integrated LED

Center air distribution button (6)

Center air distribution ON/OFF

Integrated LED

Lower air distribution button (7)

Lower air distribution ON/OFF

Integrated LED

Component description for automatic air conditioning control and operating unit

With code 581 (Automatic air conditioning)

N22/7

Automatic air conditioning control and operating unit

P83.40-4479-04

Control element

Controllable function

Operating feedback

Rear window heater button (N22/7s1)

Rear window heater ON/OFF

Integrated LED

Air recirculation mode button (N22/7s2)

Air recirculation mode ON/OFF

Integrated LED

Heated windshield defrost button (N22/7s4) (model 242.890)

Heated windshield ON/OFF

Integrated LED

Defrosting button (N22/7s4) (except model 242.890)

Defrost mode ON/OFF

Integrated LED

"A/C" button (2)

Refrigerant compressor ON/OFF

Integrated LED

Left temperature selector wheel (3.1)

Configuration of specified temperature at left

Display (16)

Right temperature selector wheel (3.2)

Configuration of specified temperature at right

Display (16)

"OFF" button (8)

Air conditioning On/Off

Integrated LED

"REST" button (9)

Residual heat utilization ON/OFF

Integrated LED

"AUTO" button (10)

Automatic mode ON/OFF

Integrated LED

"ZONE" button (11)

Take over settings of driver side for passenger side

Integrated LED

Reduce air volume button (12)

Reduce air volume

Display (16)

Increase air volume button (13)

Increase air volume

Display (16)

"MODE" button downward (14)

Change air distribution

Display (16)

"MODE" button upward (15)

Change air distribution

Display (16)

MODEL 117, 156, 242, 246
with CODE 494 (US version)
The "MAX COOL" button is installed instead of the "REST" button.

Location

The control and operating unit is located in the center console.

Task

The control and operating unit has the following tasks:

Reading in of sensors and signals

Evaluation of input factors

Actuation of components

Transmitting signals

Reading in of sensors and signals

The input factors are read in via the following connections:

Direct line

Climate control LIN (LIN B8)

Interior CAN (CAN B)

Direct line

The signals from the following sensors are read via direct lines:

Interior temperature sensor (B10/4) (with CODE 581 (Automatic air conditioning))

Evaporator temperature sensor (B10/6)

Refrigerant pressure sensor (B12/2)

Sun sensor (B32/3) (with CODE 581 (Automatic air conditioning))

Central air distribution position recognition microswitch (S24/1) (with CODE 581 (Automatic air conditioning))

Climate control LIN

The signals of the air quality sensor (B31) (with CODE 581 (Automatic air conditioning)) are read in via the climate control LIN.

Interior CAN

The following signals, among others, are read in via interior CAN:

Terminal status of terminal 15

Outside temperature

Vehicle speed

The functions that use these signals are described in the individual function descriptions (see block diagram or function schematic).

Evaluation of input factors

The input factors that have been read in are evaluated by the integrated microprocessor and the relevant components are then actuated.

Actuation of components

The components are actuated via the following connections:

Direct line

Climate control LIN

Climate control LIN (LIN B8-1) (model 242.890)

Direct line

The following components are actuated via direct lines:

A/C compressor regulating valve (A9y1) (except CODE B09 (A/C compressor with magnetic clutch))

A/C compressor regulating valve (A9/7y1) (with CODE B09 (A/C compressor with magnetic clutch))

A/C compressor magnetic clutch (A9/7y2) (with CODE B09 (A/C compressor with magnetic clutch))

Heated rear window relay (F34kD)

Coolant circulation pump (M13/5) (with CODE 581 (Automatic air conditioning) and except CODE 494 (USA version))

Front evaporator shutoff valve (Y19/3) (model 242.890)

Climate control LIN

The following components are actuated via climate control LIN:

Blower regulator (A32n1)

Central air distribution actuator motor (M2/4)

Fresh air/recirculated air flap actuator motor (M2/5)

Left blend air flap actuator motor (M2/6)

Right blend air flap actuator motor (M2/7) (with CODE 581 (Automatic air conditioning))

PTC heater booster (R22/3) (diesel engine)

Climate control LIN (model 242.890)

The following components are actuated via the climate control LIN:

Electric refrigerant compressor (A9/5)

Heater circuit circulation pump (M91/6)

High voltage PTC heater (N33/5)

Transmitting signals

The signals are transmitted by the control and operating unit via the interior CAN.

The functions that use these signals are described in the individual function descriptions (see block diagram or function schematic).

Wiring diagram for automatic air conditioning (AAC [KLA]) control unit

PE83.40-P-2101-97IAA