ar9720p1500e

Preserving hollow cavities following repair

Typ ar · téma 97.20 · verze 0105 · 2000-06-05

Platí pro: MODEL 202.0 /1

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 97 Utěsnění karosérie, protikorozní ochrana › 97.20 Konzervace — Řada 202 (modely 0**, 1**)

EinPAS 40 Konzervace/lakování › 40.20 Ochrana proti korozi › 40.20.40 Konzervace dutin — Řada 202 (modely 0**, 1**)

AR97.20-P-1500E

Preserving hollow cavities following repair

22.12.93

MODEL 202.0 /1

Preserving hollow cavities following repair

P97.20-0200-09

1 Engine hood

2 Trunk lid

5 Rear door-rubber retaining rail

6 Door channel, rear door

3 Driver's door-rubber retaining rail

4 Door channel, driver's door

Preserving hollow cavities following repair

P97.20-0202-09

Front end

7 Reinforcement-windbreak

8 A-pillar-longitudinal member, inner

12 Tunnel reinforcement

13 Spring tower

9 Fork retainer-front wall

10 Longitudinal member

11 Cross member

Preserving hollow cavities following repair

P97.20-0201-06

Front end Wheel house side member-floor assembly

14 A-pillar-wheel house

15 Longitudinal member, outer

16 Firewall reinforcement

17 Connecting carrier-wheel arch panel

18 Console-transverse link bearing, bottom

19 Engine support

Preserving hollow cavities following repair

P97.20-0203-09

Rear end

20 Rear end center assembly

21 Longitudinal member-wheel arch panel

24 Cross member-rear axle

25 Mounting

22 Longitudinal member, outer

23 Wheel house inner - rear fender

Fig. item, etc.

Work instructions

Danger!

Risk of explosion and poisoning through solvent vapors and gases. Risk of injury to eyes and skin when handling anti-corrosion agents

Do not spray anti-corrosion agent into flames or onto glowing-hot surfaces and keep away from ignition sources. Work only in well ventilated areas, wear protective respiratory mask.

AS97.00-Z-0001-01A

Notes on hollow cavity preservation

AH97.20-P-0001-01B

Processing instructions for hollow cavity preservation

AP97.20-P-0640-01A

Apply wax preservative on hatched areas only after sealing and painting work, but before assembly work.

Insert spray hose as far as possible into cavities and pull out slowly during spraying.

Spray hose must be stiff and jets must spray inclined to front and rear. Cavities must be dry.

Carry out repair preservation twice in succession after a flash-off time of 5 minutes.

Application temperature must not be below +15 °C.

Apart from the standard cavity preservation as shown, additional sealing measures may be required depending on area of repair.